RMI-QE installation guide
2.6
RMI-QE basics
•
“On” resistance = 50
W
max.
•
Load voltage
= 40 V max.
•
Load current
= 100 mA max.
•
Load current
= 50 mA max.
•
Load current
= 50 mA max.
RMI-QE outputs
There are five outputs:
•
Probe status 1 (SSR).
•
Probe status 2a (5 V isolated driven skip).
•
Probe status 2b (driven at power supply voltage).
•
Error (SSR).
•
Low battery (SSR).
All outputs can be inverted by using switches SW1 and SW2, (see page 2.10,
“Switches SW1 and
SW2”
, for further information).
Probe status 1, Error, Low battery (SSR):
Probe status 2a (5 V isolated driven skip):
Output voltages
Probe status 2b (driven at power supply voltage):
Output voltages
The “LOW BATTERY/START”, “PROBE STATUS”, “ERROR” and “SIGNAL” LEDs will start flashing red
when an output overload has occurred. All outputs will be switched off. If this occurs, turn off the power
supply and remove the source of the problem. Turning on the power supply will reset the RMI-QE.
•
Sourcing voltage drop
= 4.2 V max. at 10 mA.
= 2.2 V min. at 50 mA.
•
Sinking voltage drop
= 0.4 V max. at 10 mA.
= 1.3 V max. at 50 mA.
•
Sourcing voltage drop
= 4.2 V max. at 10 mA.
= 2.2 V min. at 50 mA.
•
Sinking voltage drop
= 0.4 V max. at 10 mA.
= 1.3 V max. at 50 mA.
Summary of Contents for RMI-QE
Page 1: ...RMI QE radio machine interface Installation guide H 6551 8520 01 A...
Page 6: ...RMI QE installation guide iv Contents This page is intentionally left blank...
Page 26: ...RMI QE installation guide 2 16 RMI QE basics This page is intentionally left blank...
Page 44: ...RMI QE installation guide 3 18 System installation This page is intentionally left blank...
Page 48: ...RMI QE installation guide 4 4 Maintenance This page is intentionally left blank...
Page 53: ......