Problem
Possible cause
Corrective action
No air and no abra-
sive.
• Blasting nozzle blocked at the
hand-piece.
• Foot switch connecting lines
kinked.
• Unscrew the nozzle from the hand-piece and
blow it out.
• With the nozzle removed, blow out the blast-
ing hose by activating the foot pedal.
• Inspect/correct the connection lines.
Only air, no or very
little abrasive.
• The dosage nozzle in the mix-
ing chamber is blocked due to
contaminated or moist sand.
• Mixing chamber filter combina
-
tion blocked.
• Abrasive contains impurities or
is moist.
• Cleaning the dosing nozzle, see chapter 5.4.
• Change filter cartridge (Wrench SW14).
• Replace the abrasive.
Unit blasts continu-
ously.
• Foot switch connected incor-
rectly.
• Valve in foot switch is defec-
tive.
• Inspect / correct the foot switch connection.
• Replace foot switch.
Compressed air
leaking from the
foot switch.
• Pneumatic hoses reversed.
• Reverse the connections.
Foot switch fails to
switch on.
• No pressure at the com-
pressed air connection.
• Pneumatic hoses are kinked.
• Inspect the compressed air lines and / or the
compressor.
• Reposition the hoses.