Renesas ZMOD4410 User Manual Download Page 1

 

ZMOD4410 Evaluation Kit User Manual 

 

© 2020 Renesas Electronics Corporation 

June 3, 2020 

 

Description 

The ZMOD4410 Evaluation Kit (EVK) is designed for evaluating 

Renesas’ ZMOD4410 Gas Sensor Module for Indoor Air Quality. 

The total volatile organic compounds (TVOC) measurement is one 

of the indicators for indoor air quality (IAQ).  In  addition, 

measurement modes are  provided  to  trigger an external device 

(e.g., fan, ventilation)  based on the air quality change,  and to 

discriminate sulfur odors.  
The  Gas Sensor Evaluation Software  allows  Windows

®

-based 

operating systems to communicate with the ZMOD4410 EVK via a 

USB connection on the user’s computer, which functions as a 

master. The software and additional related documentation is 

available on the Renesas website  at www.IDT.com/ZMOD4410-

EVK.  
The EVK’s Communication Board (HiCom) handles the interface 

between the user’s computer and the ZMOD4410 module mounted 

on the ZMOD4410 Sensor Board (i.e., daughter board). Note: Only 

one  Communication Board with  one Sensor Board  can be 

connected to the computer at a time.  
The  ZMOD4410  Evaluation Kit  uses an FTDI  controller  on the 

Communication Board to handle the USB protocol, translate 

communications, and synchronize communications with the I2C 

interface. The Sensor Board includes a decoupling capacitor.  
The Communication Board has devices mounted on both sides. 

The components on the top side generate a stable supply voltage. 

A potentiometer can be used to adjust the internal supply voltage 

in the typical range from 1.7V to 3.6V. Alternatively, the user’s 

external supply voltage can be used. The intensity of the adjacent 

LED is proportional to the supply voltage.

Features

 

 

User-friendly EVK expedites configuration and evaluation of 

the ZMOD4410 Gas Sensor Module 

 

Supports different methods of operation, including Low Power 

and AI technology for improved ppm TVOC readings 

 

Operates with Renesas provided software; either with 

executable ZMOD4410 GUI or alternatively with firmware 

programming examples for Windows

®

 and Linux

®

  

 

The modular design of the EVK allows simple connection of 

Sensor Boards for different gas sensor derivatives and easy 

integration with other sensor products via the I2C interface  

 

The required Gas Sensor Evaluation Software is available for 

free download on the Renesas website, which also provides 

background information on IAQ, TVOC, gas sensing, and how 

to use the sensor firmware. 

 

Additional pins to measure power consumption, supply 

voltage, and GPIO trigger for external device 

 

The bill of materials (BOM) and schematics for the ZMOD4410 

Communication Board and Sensor Board are included in this 

document. 

ZMOD4410-EVK Contents 

 

HiCom Communication Board 

 

Sensor Board with ZMOD4410 Gas Sensor Module  

 

0.5m Type-B USB to Micro-USB Cable  

ZMOD4410 Evaluation Kit 

 

Summary of Contents for ZMOD4410

Page 1: ...or The Communication Board has devices mounted on both sides The components on the top side generate a stable supply voltage A potentiometer can be used to adjust the internal supply voltage in the typical range from 1 7V to 3 6V Alternatively the user s external supply voltage can be used The intensity of the adjacent LED is proportional to the supply voltage Features User friendly EVK expedites ...

Page 2: ...ation Block 11 2 4 Error Codes 11 3 Schematics 12 4 Bill of Materials BOM 15 5 Board Layout 18 6 Ordering Information 20 7 Revision History 20 List of Figures Figure 1 Initial Display after Starting the Sensor Evaluation Software 5 Figure 2 Jumper Settings and Connectors on Top Side of the ZMOD4410 Communication Board 6 Figure 3 Jumper Settings Connections and Test Points on the Communication Boar...

Page 3: ...ne 3 2020 List of Tables Table 1 Evaluation Kit Connection Descriptions 6 Table 2 Sample Rates 9 Table 3 Analysis Tab User Options 9 Table 4 Most Common Error Messages 11 Table 5 Communication Board BOM 15 Table 6 Sensor Board BOM 17 Table 7 PIN Configuration on Connector X1 17 ...

Page 4: ...dows 10 Internet access for initial download of the drivers and software Important Before installing and activating the software assemble and connect the hardware for the kit to the user s computer according to steps 1 through 3 in section 1 5 1 4 Software Installation and Setup Before using the Gas Sensor Evaluation Software the USB drivers for the FTDI device must be installed Download the drive...

Page 5: ...on Board taking care to ensure the proper orientation of the Sensor Board is as shown on page 1 3 Insert the micro USB cable into the X1 connector on the Communication Board and connect it to a free USB port on the user s computer If the external voltage supply has been selected turn on the external supply and verify that the D3 LED adjacent to the potentiometer is on See Figure 2 Note The intensi...

Page 6: ...that can be controlled via the software in the Odor measurement mode K4 14 pin connector This is the connector for installing the ZMOD4410 Sensor Board on the Communication Board K5 2 pin header This is the connector for an optional external voltage supply see Figure 3 D1 Status LED This LED lights if the Communication Board is powered correctly see Figure 2 D2 Status LED This LED lights if the so...

Page 7: ...4410 Evaluation Kit User Manual 2020 Renesas Electronics Corporation 7 June 3 2020 Figure 3 Jumper Settings Connections and Test Points on the Communication Board for the Internal or External Supply Voltage ...

Page 8: ...nsor Evaluation Software is started the initial window is displayed as shown in Figure 4 The initial display in all operation modes consists of three blocks Measurement Control Signal Analysis Plot Visualization Figure 4 Initial Display for the ZMOD4410 Start Up Measurement Control Signal Analysis Plot Visualization ...

Page 9: ...and Options Depending in the operation mode IAQ 1st Gen Continuous IAQ 1st Gen Low Power IAQ 2nd Gen Odor or Sulfur Odor Discrimination the user will see slightly different options While IAQ 1st Gen uses traditional computing algorithms the IAQ 2nd Gen uses embedded AI technology for improved ppm TVOC The available user options are described in Table 3 for all measurement modes Table 3 Analysis Ta...

Page 10: ...or signals are shown on the Sensor Signal Ohms plot during this time but the algorithm results are only calculated after stabilization Note that this does not cover the full stabilization of the sensor module but rather covers only the first minutes during startup If the sensor is in operation but does not report any algorithm output check the available demo mode for Baseline Optimization in the A...

Page 11: ...startup of the EVK Other common error messages are explained in Table 4 Table 4 Most Common Error Messages Error Code Description and Solution Cannot connect to hardware Have you installed the FTDI D2XX driver Is the hardware connected Please check if the FTDI driver is installed properly and the hardware is connected Note that during the initial startup of the EVK software the HiCom must be conne...

Page 12: ...ZMOD4410 Evaluation Kit User Manual 2020 Renesas Electronics Corporation 12 June 3 2020 3 Schematics Figure 5 Communication Board Schematic Page 1 ...

Page 13: ...ZMOD4410 Evaluation Kit User Manual 2020 Renesas Electronics Corporation 13 June 3 2020 Figure 6 Communication Board Schematic Page 2 ...

Page 14: ...ZMOD4410 Evaluation Kit User Manual 2020 Renesas Electronics Corporation 14 June 3 2020 Figure 7 Sensor Board Schematic ...

Page 15: ...nF 0603 10 C13 100nF 0603 11 C14 100nF 0603 12 C15 100nF 0603 13 C16 100nF 0603 14 C17 10µF 16V 0805 15 C18 27pF 0603 16 C19 27pF 0603 17 C20 10µF 16V 0805 18 C21 10µF 16V 0805 19 C22 100nF 0603 20 C23 100nF 0603 21 C24 10µF 16V 0805 22 C25 100nF 0603 23 C26 100nF 0603 24 C27 10µF 16V 0805 25 C28 100nF 0603 26 C29 10µF 16V 0805 27 C30 100nF 0603 28 C31 220nF 0805 29 D1 LED 1206RT 1206 DIODE 30 D2 ...

Page 16: ...2X7 LH 14 43 K5 V_EXT 1X02 44 L1 10µH 1210 45 L2 10µH 1210 46 L3 10µH 1210 47 Modul1 Honeywell480 3652 1 ND DIL8 SMD SOCKEL 48 Q1 12 00MHz QUARZ ABM3 49 R1 1kΩ 0805 50 R2 1kΩ 0805 51 R3 1 6kΩ 0805 52 R4 12kΩ 0805 53 R5 47kΩ 0805 54 R6 2 2kΩ 0805 55 R7 10kΩ 0805 56 R8 1kΩ 0805 57 R13 51Ω 0805 58 R15 51Ω 0805 59 R16 10Ω 0805 60 R17 1kΩ 0805 61 R18 470Ω 0805 62 R19 2 0kΩ TRIMMER 3142SERIES 63 R20 1kΩ...

Page 17: ...or Quantity Manufacturer Manufacturer Part Number C1 1 Murata GRM155R70J105KA12D R4 1 Yageo RC0402JR 0710KL U1 1 Renesas ZMOD4410 X1 1 Sullins SFH11 PBPC D07 ST BK Table 7 PIN Configuration on Connector X1 Pin Number Pin Description 1 VDD 2 n c 3 n c 4 n c 5 SCL 6 RES_N 7 SDA 8 n c 9 n c 10 INT 11 n c 12 n c 13 n c 14 GND ...

Page 18: ...4410 Evaluation Kit User Manual 2020 Renesas Electronics Corporation 18 June 3 2020 5 Board Layout Figure 8 HiCom Communication Board Layout Top Layer Figure 9 HiCom Communication Board Layout Bottom Layer ...

Page 19: ...4410 Evaluation Kit User Manual 2020 Renesas Electronics Corporation 19 June 3 2020 Figure 10 Sensor Board Layout Top Layer with PIN Configuration on Connector X1 Figure 11 Sensor Board Layout Bottom Layer ...

Page 20: ...on Software is available for download free of charge on www IDT com ZMOD4410 EVK 7 Revision History Revision Date Description of Change June 3 2020 Added IAQ 2nd Gen method of operation Added Sulfur odor Discrimination method of operation Updated the Gas Sensor Evaluation software version Updated the link to the FTDI driver Updated the stabilization time Added Error Codes November 1 2018 Updated w...

Page 21: ...re intended for developers skilled in the art designing with Renesas products You are solely responsible for 1 selecting the appropriate products for your application 2 designing validating and testing your application and 3 ensuring your application meets applicable standards and any other safety security or other requirements These resources are subject to change without notice Renesas grants yo...

Reviews: