Section 13 Timer Array Unit B (TAUB)
(5)
Register settings for slave channels
(a)
TAUBnCMORm for slave channels
(b)
TAUBnCMURm for slave channels
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
TAUBnCKS
[1:0]
TAUBnCCS
[1:0]
TAUB
nMAS
TAUBnSTS[2:0]
TAUBnCOS
[1:0]
-
TAUBnMD[4:1]
TAUBn
MD0
Table 13-70
TAUBnCMORm Settings for Slave Channels of PWM Output Function
Bit Name
Setting
TAUBnCKS[1:0]
00: Prescaler output CK0
01: Prescaler output CK1
10: Prescaler output CK2
11: Prescaler output CK3
TAUBnCKS[1:0] bits of master and slave channels should have
the same value.
TAUBnCCS[1:0]
00: Uses an operation clock as a count clock.
TAUBnMAS
0: Slave channel
TAUBnSTS[2:0]
100: INTTAUBnIm of master channel is a start trigger.
TAUBnCOS[1:0]
00: Unused. Set to 00.
TAUBnMD[4:1]
0100: One-count mode
TAUBnMD0
1: Start trigger during operation is valid.
7
6
5
4
3
2
1
0
-
TAUBnTIS[1:0]
Table 13-71
TAUBnCMURm Settings for Slave Channels of PWM Output Function
Bit Name
Setting
TAUBnTIS[1:0]
00: Unused. Set to 00.