R01UH0336EJ0102 Rev.1.02
Page 268 of 1538
Jul 17, 2014
V850E2/PG4-L
Section 7 Clock Generation
7.8 Clock Monitor A (CLMAn) Function
This product has three instances of the clock monitor A.
7.8.1
Features of the Clock Monitors (CLMAn; n = 0, 1, 2)
Instances index n
Throughout this section, the individual instances of a clock monitor A are
identified by the index "n" (n = 0 to 2), for example, CLMAnCTL0 for the control
register 0 of CLMAn.
<CLMAn_base>
The base address <CLMAn_base> of each CLMAn is listed in the table below.
Clock supply
The monitored and the sampling clocks of all clock monitors A are listed in the
following table:
Table 7-10
Instances
Clock Monitor A
Number of
instances
3
Name
CLMAn
Table 7-11
Register Base Address <CLMAn_base>
CLMAn
<CLMAn_base> Address
CLMA0
FF80_2000
H
CLMA1
FF80_3000
H
CLMA2
FF80_4000
H
Table 7-12
CLMAn Clock Supply
Clocks for CLMAn
Function
Connected to
CLMA0:
CLMA0TSMP
Sampling clock for CLMA0
Internal OSC
CLMA0TMON
Clock for monitoring by CLMA0
WDTCLKI
CLMA1:
CLMA1TSMP
Sampling clock for CLMA1
Main OSC
CLMA1TMON
Clock for monitoring by CLMA1
Internal system clock
CLMA2:
CLMA2TSMP
Sampling clock for CLMA2
Main OSC
CLMA2TMON
Clock for monitoring by CLMA2
Internal OSC