R01UH0336EJ0102 Rev.1.02
Page 1362 of 1538
Jul 17, 2014
V850E2/PG4-L
Section 24 Peripheral Interconnection (PIC)
24.4 Connection Functions
24.4.1
Simultaneous Start Trigger Function
24.4.1.1
Functional Overview
Allows any combination of the timers (TAUB0, TAUJ0, TSG20, TPBA0,
OSTMn, and ENCA0) to be started simultaneously.
24.4.1.2
Configuration
Configuration/Timer
Function
Timer
Timer configuration
TAUB0, TAUJ0, TSG20, TPBA0, OSTMn, ENCA0