![Renesas RH850/U2A 144pin User Manual Download Page 43](http://html1.mh-extra.com/html/renesas/rh850-u2a-144pin/rh850-u2a-144pin_user-manual_1440419043.webp)
RH850/U2A 144pin
8. Jumper Configuration Examples
R20UT5089ED0101 Rev.1.01
Page 37 of 56
July 08, 2022
8.2.5
Stand-Alone Operation with All External Power Supplies: Maximum Configuration
This example assumes all external power supplies are connected and used.
•
CN8: GND connection
•
CN9: 5 V
•
CN10: 3.3V
−
select desired 3.3 V/5.0 V via jumpers JP1, JP6 to JP8, JP10 to JP13, JP33, JP35 and JP37
•
CN11: 1.12 V (IN_1v12)
−
JP16[2-3], JP23[2-1]: use IN_1v12 for VDD voltage
Refer to
3.3 Device Core Voltage (VDD) Selection
for further details about VDD voltage.
Figure 8.3 Stand-alone operation with maximum external power supply