Voice over PLC Sample Application Operating Manual

     

 

3. Operating procedure 

R11UM0083EJ0200  Rev.2.00 

 

Page  4  of 9 

June 25, 2018 

 

RENESAS CONFIDENTIAL 

 

RENESAS Group CONFIDENTIAL 

 
 
 

User specifies the destination Node IDs in decimal. If the Node ID is one, unicast transmission is 

started, if the Node ID is multiple, multicast transmission is started. When specifying multiple Node IDs, 
the user specifies the node IDs separated by spaces.

 

 

3.3.2  Duplex 

 

User specifies the destination Node ID in decimal. Only one Node ID is specified.

 

 

3.4  Data Send menu 

 

User specifies the destination Node ID in decimal. Only one Node ID is specified.

 

 

 

Continuously, the user sets the sending data in hexadecimal. The maximum data size that can be 

transmitted is 64 bytes. Sending data must be entered consecutively without separating.

 

 

3.5  Setting menu 

 

1. 

Menu for initializing EEPROM.

 

2. 

Menu for individually editing the set values.

 

3. 

Menu for displaying the current set value.

 

4. 

Menu for erasing EEPROM.

 

 

The sample application reads the initial setting value from EEPROM and starts application process. 

When invalid value is written in EEPROM, sample application starts with the default setting value. The 
default setting values are follows.

 

Extend Addr 

: 0xABCDABCDABCD0000 

Node ID  

: 000 

Bitrate   

: 32000 

Sampling Rate 

: 8000 

Modulation 

: BPSK 

 

3.5.1  Initialization for EEPROM 

The value of EEPROM is changed to the default value. The default values are follows. 

Extend Addr 

: 0xABCDABCDABCD0000 

Node ID  

: 000 

Bitrate   

: 32000 

Sampling Rate 

: 8000 

Modulation 

: BPSK 

 

Dest Node ID> 

--------------------------------------------- 
Dest Node ID> 

Send Data( 01FF...)> 

1: Init config 
2: Edit config 
3: Disp config 
4: Erase config 
--------------------------------------------- 

Summary of Contents for J80D1

Page 1: ...ned in these materials including products and product specifications represents information on the product at the time of publication and is subject to change by Renesas Electronics Corp without notic...

Page 2: ......

Page 3: ...p power on reset function are not guaranteed from the moment when power is supplied until the power reaches the level at which resetting has been specified 3 Prohibition of Access to Reserved Addresse...

Page 4: ...3 4 Data Send menu 4 3 5 Setting menu 4 3 5 1 Initialization for EEPROM 4 3 5 2 Individual editing for EEPROM 5 3 5 3 Displaying the EEPROM setting value 6 3 5 4 Erasing EEPROM setting value 6 3 6 Vo...

Page 5: ...Overview This document is the operating manual which is descriptive of the Voce over PLC sample application for BCPX3 Evaluation Kit J80D1 The sample application controls voice communication using the...

Page 6: ...r audio board Figure 2 1 system configuration of sample application 2 2 Hardware setting Set the J80D1 board to use MCU RX651 Switches and Jumpers Setting SW1 Turn OFF all the SWs SW5 MCU SW6 USE Refe...

Page 7: ...ain menu 1 Menu to call when starting voice communication 2 Menu to send binary data 3 Menu to edit the contents of EEPROM 4 Menu to change the input and output volume When the above menu number is se...

Page 8: ...that can be transmitted is 64 bytes Sending data must be entered consecutively without separating 3 5 Setting menu 1 Menu for initializing EEPROM 2 Menu for individually editing the set values 3 Menu...

Page 9: ...d address must be set in hexadecimal 2 Editing Node ID Node ID from 0 to 127 must be set in decimal 3 Editing Bitrate Bitrate must be set in decimal The settable bit rate is 8000 to 32000 4 Editing Sa...

Page 10: ...gain 3 6 1 Changing input volume The ADC gain must be set with signed decimal The settable gain is 12dB to 20dB The default value is 2dB 3 6 2 Changing output volume The DAC gain must be set with sig...

Page 11: ...r is calling 6 Loop back State in which the microphone input of the audio board is output from the speaker of the audio board The state transition diagram is as follows Figure 4 1 State transition dia...

Page 12: ...e 4 3 Listening state 1 Menu to end voice communication 2 Menu to send binary data 3 Menu to change the input and output volume 4 4 Talking state 1 Menu to end voice communication 2 Menu to change the...

Page 13: ...State information R11UM0083EJ0200 Rev 2 00 Page 9 of 9 June 25 2018 RENESAS CONFIDENTIAL RENESAS Group CONFIDENTIAL 4 6 Loop back state 1 Menu to end voice communication 2 Menu to change the input and...

Page 14: ...Description Page Summary 1 00 December 1 2017 First Edition issued 2 00 June 25 2018 7 9 Correction of errors 3 4 Add Simplex and Duplex in Call menu 4 6 Add Modulation in Setting menu 6 Add 3 7 Note...

Page 15: ...Voice over PLC Sample Application Operating Manual Publication Date Rev 2 00 June 25 2018 Published by Renesas Electronics Corporation...

Page 16: ......

Page 17: ...Voice over PLC Sample Application Operating Manual R11UM0083EJ0200...

Reviews: