![Renesas IDT Tsi574 User Manual Download Page 289](http://html1.mh-extra.com/html/renesas/idt-tsi574/idt-tsi574_user-manual_1440935289.webp)
12. Serial RapidIO Registers > RapidIO Error Management Extension Registers
289
Tsi574 User Manual
June 6, 2016
Integrated Device Technology
www.idt.com
12.7.10
RapidIO Port x Error Rate Enable CSR
This register contains the bits that control when an error condition is allowed to increment the error rate
counter. and be captured in the error capture register.
Each write of a non-zero value to the
“RapidIO Port x Error Detect CSR” on page 286
causes the Error
Rate Counter to increment, if the corresponding error bit is enabled in the Port x Error Rate Enable
CSR. When the threshold is reached, hardware informs the system software of the error using its
standard error reporting function. After the error has been reported, the system software can read and
clear registers as necessary to complete its error handling protocol testing.
Register name: SP{0..7}_RATE_EN
Reset value: 0x0000_0000
Register offset: 1044, 1084, 10C4, 1104, 1144, 1184,
11C4, 1204
Bits
0
1
2
3
4
5
6
7
00:07
IMP_SPEC
_ERR
Reserved
08:15
Reserved
CS_CRC_E
RR_EN
CS_ILL_ID
_EN
CS_NOT_A
CC_EN
PKT_ILL_A
CKID_EN
PKT_CRC_
ERR_EN
PKT_ILL_S
IZE_EN
Reserved
16:23
Reserved
24:31
Reserved
LR_
ACKID_
ILL_EN
PROT_
ERR_EN
Reserved
DELIN_
ERR_EN
CS_ACK_
ILL_EN
LINK_TO_E
N
Bits
Name
Description
Type
Reset
Value
0
IMP_SPEC_ERR
Logical /Transport Error Enable
Enable error rate counting of implementation specific errors.
See the
“RapidIO Port x Error Detect CSR” on page 286
for a
description of the errors applicable to this field.
Caution: The Error Capture register information is only valid for
Reserved Transport Type Detected errors and Unmapped DestID
errors. For the Max Retry errors the information latched is the last
packet received, not the packet that was retried.
For more information on error capture, see
Capture Attributes CSR and Debug 0” on page 291
.
R/W
0
1:8
Reserved
N/A
R
0
9
CS_CRC_ERR_
EN
Enable error rate counting.
Received Control Symbol with a CRC error.
R/W
0
10
CS_ILL_ID_EN
Enable error rate counting.
Received an acknowledge control symbol with an unexpected
ackID (packet-accepted or packet_retry).
R/W
0