background image

 

 

H8SX/1520 Group FP-100M 

User System Interface Cable 

User’s Manual 

Renesas Microcomputer Development Environment System 

HS1527ECH61H 

 

Rev.1.00

 

Revision Date: Jan. 12, 2005

 

REJ10B0173-0100 

Summary of Contents for H8SX/1520 Series

Page 1: ...H8SX 1520 Group FP 100M User System Interface Cable User s Manual Renesas Microcomputer Development Environment System HS1527ECH61H Rev 1 00 Revision Date Jan 12 2005 REJ10B0173 0100...

Page 2: ...fore making a final decision on the applicability of the information and products Renesas Technology Corp assumes no responsibility for any damage liability or other loss resulting from the informatio...

Page 3: ...H is a user system interface cable that connects an H8SX 1520 group E6000H emulator HS1527KEPH60H hereinafter referred to as the emulator to the IC socket for an FP 100M package for the H8SX 1520 grou...

Page 4: ...IC Socket 5 2 2 2 Soldering IC Socket 5 2 2 3 Inserting Cable Head 6 2 2 4 Fastening Cable Head 6 2 2 5 Fastening Cable Body 8 2 3 Recommended Dimensions for User System Mount Pad 9 2 4 Dimensions for...

Page 5: ...the user system Figure 1 shows the configuration of the HS1527ECH61H user system interface cable for the FP 100M package To emulator station Cable body User system IC socket Cable head Screws M2 6 x 1...

Page 6: ...ity Remarks 1 Cable body 1 Cable 2 Cable head 1 3 IC socket 1 For the FP 100M package 4 Socket cover 1 For installing an FP 100M packaged MCU 5 Screws M2 6 x 12 mm 4 For fastening cable head with four...

Page 7: ...M INTERFACE CABLE is connected to or removed from any part Before connecting make sure that pin 1 on both sides are correctly aligned 2 The user system interface cable dedicated to the emulator must b...

Page 8: ...connector is correct firmly insert the cable body connector into the emulator station socket figure 2 E6000H HS1527KEPH60H emulator station RENESAS Cable body connector User system interface cable Fi...

Page 9: ...sult in PERSONAL INJURY The USER PROGRAM will be LOST To connect the cable head to the user system follow the instructions below 2 2 1 Installing IC Socket After checking the location of pin 1 on the...

Page 10: ...rewdriver whose head matches the screw head 2 The tightening torque must be 0 0785 N m or less If the applied torque cannot be accurately measured stop tightening when the force required to turn the s...

Page 11: ...rnating between screws on opposing corners Take special care such as manually securing the IC socket soldered area to prevent the soldered IC socket from being damaged by overtightening the screws or...

Page 12: ...8 2 2 5 Fastening Cable Body Connect the cable body to the cable head Cable body Cable head Remove jig Push the remove jigs User system Removing Figure 4 Fastening Cable Body...

Page 13: ...th an IC socket for an FP 100M package IC149 100 054 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd Note that the dimensions in figure 5 are somewhat different from those of the actual chip s mount p...

Page 14: ...ser System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6 63 50 66 04 17 0 17 0 29 5 29 5 Unit mm Tolerance 0 5 mm Figure 6 Dimensions for User Syst...

Page 15: ...fter connecting the user system interface cable head to the user system are shown in figure 7 16 0 21 5 Cable head User system Unit mm Tolerance 0 5 mm IC socket IC149 100 054 B51 manufactured by YAMA...

Page 16: ...head may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MCU does not operate correctly cracks might have occurred in the solder Check conduction with a...

Page 17: ...13 MCU Pin 1 IC socket IC149 100 054 B51 manufactured by YAMAICHI ELECTRONICS Co Ltd User system Screws M2 6 x 6 mm with flat washers Socket cover Figure 8 Installing MCU to User System...

Page 18: ...50 E6000H Emulator User s Manual HS1650EPH60HE To use the emulator internal clock Select the clock in the emulator by using the CLOCK command emulator command To use the external clock on the user sys...

Page 19: ...lator station is connected to the user system with the user system interface cable force must not be applied to the cable head Place the emulator station user system interface cable and user system as...

Page 20: ...ges of AVcc0 and AVcc1 refer to the H8SX 1520 Group Hardware Manual CAUTION Insert the jumper pin in the P4 short connector so that the higher voltage between AVcc0 and AVcc1 is selected Select either...

Page 21: ...er System Interface Cable Publication Date Rev 1 00 January 12 2005 Published by Sales Strategic Planning Div Renesas Technology Corp Edited by Technical Documentation Information Department Renesas K...

Page 22: ...Fax 44 1628 585 900 Renesas Technology Hong Kong Ltd 7th Floor North Tower World Finance Centre Harbour City 1 Canton Road Tsimshatsui Kowloon Hong Kong Tel 852 2265 6688 Fax 852 2730 6071 Renesas Tec...

Page 23: ...H8SX 1520 Group FP 100M User System Interface Cable HS1527ECH61H User s Manual...

Reviews: