background image

 

To our customers, 

 

Old Company Name in Catalogs and Other Documents 

 

On April 1

st

, 2010, NEC Electronics Corporation merged with Renesas Technology 

Corporation, and Renesas 

Electronics Corporation 

took over all the business of both 

companies. 

Therefore, although the old company name remains in this document, it is a valid 

Renesas 

Electronics document. We appreciate your understanding. 

 

Renesas Electronics website: 

http://www.renesas.com

 

 
 
 
 

April 1

st

, 2010 

Renesas Electronics Corporation 

 

 
 
 
 

Issued by: 

Renesas Electronics Corporation

 (

http://www.renesas.com

Send any inquiries to 

http://www.renesas.com/inquiry

 

Summary of Contents for H8S/2655 Series

Page 1: ...ook over all the business of both companies Therefore although the old company name remains in this document it is a valid Renesas Electronics document We appreciate your understanding Renesas Electronics website http www renesas com April 1st 2010 Renesas Electronics Corporation Issued by Renesas Electronics Corporation http www renesas com Send any inquiries to http www renesas com inquiry ...

Page 2: ...ct for an application categorized as Specific or for which the product is not intended where you have failed to obtain the prior written consent of Renesas Electronics The quality grade of each Renesas Electronics product is Standard unless otherwise expressly specified in a Renesas Electronics data sheets or data books etc Standard Computers office equipment communications equipment test and meas...

Page 3: ...H8S 2655 Series TQFP 120 User System Interface Cable HS2655ECN61H for E6000 Emulator User s Manual User s Manual ...

Page 4: ...of bodily injury such as aerospace aeronautics nuclear power combustion control transportation traffic safety equipment or medical equipment for life support 4 Design your application so that the product is used within the ranges guaranteed by Renesas particularly for maximum rating operating supply voltage range heat radiation characteristics installation conditions and other characteristics Rene...

Page 5: ...s original microcomputer H8S 2655 series The HS2655ECN61H is a user system interface cable that connects an H8S 2655 series E6000 emulator HS2655EPI61H hereinafter referred to as the emulator to the IC socket for a TQFP 120 package package code TFP 120 for the H8S 2655 series MCU on the user system ...

Page 6: ... IC Socket 5 2 2 2 Soldering IC Socket 6 2 2 3 Inserting Cable Head 6 2 2 4 Fastening Cable Head 6 2 2 5 Fastening Cable Body 8 2 3 Recommended Dimensions for User System Mount Pad 9 2 4 Dimensions for User System Interface Cable Head 10 2 5 Resulting Dimensions after Connecting User System Interface Cable 11 Section 3 Installing the MCU to the User System 12 Section 4 Verifying Operation 14 Secti...

Page 7: ...N Use an IC149 120 043 B5 socket manufactured by YAMAICHI ELECTRONICS Co Ltd for the TFP 120 package IC socket on the user system Figure 1 shows the configuration of the HS2655ECN61H user system interface cable for the TFP 120 package ...

Page 8: ...Figure 1 HS2655ECN61H User System Interface Cable 2 ...

Page 9: ... Remarks 1 Cable body 1 Includes flat cable 2 Cable head 1 3 IC socket 1 For the TFP 120 package 4 Socket cover 1 For installing a TFP 120 packaged MCU 5 Screws M2 x 12 mm 4 For fastening cable head with four flat washers 6 Screws M2 x 8 mm 4 For installing a TFP 120 packaged MCU with four flat washers 7 Documentation 1 User s manual for HS2655ECN61H this manual ...

Page 10: ...ake sure that pin 1 on both sides are correctly aligned 2 The user system interface cable dedicated to the emulator must be used To connect the cable body to the emulator station follow the instructions below 1 Make sure the user system and emulator station are turned off CAUTION When connecting or removing the user system interface cable apply force only in the direction suitable for connection o...

Page 11: ...removed from any part Before connecting make sure that pin 1 on both sides are correctly aligned Failure to do so will damage the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST To connect the cable head to the user system follow the instructions below 2 2 1 Installing IC Socket After checking the location of pin 1 on the IC socket apply epoxy r...

Page 12: ...able head into the IC socket on the user system as shown in figure 3 2 2 4 Fastening Cable Head CAUTION 1 Use a Phillips type screwdriver whose head matches the screw head 2 The tightening torque must be 0 098 N m or less If the applied torque cannot be accurately measured stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening...

Page 13: ...nating between screws on opposing corners Take special care such as manually securing the IC socket soldered area to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components Pin 1 Cable head IC socket IC149 120 043 B5 manufactured by YAMAICHI ELECTRONICS Co Ltd User system Screws M2 x 12 mm with flat washers Figure 3 Connecting User System Interface...

Page 14: ...2 2 5 Fastening Cable Body Connect the cable body to the cable head Cable body Cable head Remove jig Push the remove jig Removing User system Figure 4 Fastening Cable Body 8 ...

Page 15: ...h an IC socket for a TFP 120 package IC149 120 043 B5 manufactured by YAMAICHI ELECTRONICS Co Ltd Note that the dimensions in figure 5 are somewhat different from those of the actual chip s mount pad Unit mm 0 40 0 05 0 25 0 05 0 40 x 29 11 60 0 05 0 40 x 29 11 60 0 05 13 80 max 17 10 min 0 40 0 05 Figure 5 Recommended Dimensions for Mount Pad 9 ...

Page 16: ...2 4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6 Figure 6 Dimensions for User System Interface Cable Head 10 ...

Page 17: ...nnecting User System Interface Cable The resulting dimensions after connecting the user system interface cable head to the user system are shown in figure 7 Figure 7 Resulting Dimensions after Connecting User System Interface Cable 11 ...

Page 18: ...ew head may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MCU does not operate correctly cracks might have occurred in the solder Check conduction with a tester and re solder the IC socket if necessary Check the location of pin 1 before inserting the MCU into the IC socket on the user system as shown in figure 8 After inserting the MCU fasten the soc...

Page 19: ...MCU Pin 1 IC socket IC149 120 043 B5 manufactured by YAMAICHI ELECTRONICS Co Ltd User system Screws M2 x 8 mm with flat washers Socket cover Figure 8 Installing MCU to User System 13 ...

Page 20: ... MCU clock an emulator internal clock and an external clock on the user system For details refer to the H8S 2655 series E6000 Emulator Supplementary Information HS2655EPI61HE To use the emulator internal clock Select the clock in the emulator station as the system clock φ by using the CLOCK command emulator command To use the external clock on the user system Supply the external clock from the use...

Page 21: ...cifically designed for the HS2655EPI61H emulator Do not use this cable with any other emulator station 4 To prevent breaking of wires in the cable body do not place heavy or sharp metal objects on the user system interface cable 5 While the emulator station is connected to the user system with the user system interface cable force must not be applied to the cable head Place the emulator station us...

Page 22: ...6 The JP1 jumper connector is used for testing Do not remove the inserted jumper pin JP1 Figure 11 JP1 Jumper Connector 16 ...

Reviews: