background image

 

To our customers, 

 

Old Company Name in Catalogs and Other Documents 

 

On April 1

st

, 2010, NEC Electronics Corporation merged with Renesas Technology 

Corporation, and Renesas Electronics Corporation took over all the business of both 
companies. Therefore, although the old company name remains in this document, it is a valid 
Renesas Electronics document. We appreciate your understanding. 
 

Renesas Electronics website: 

http://www.renesas.com

 

 
 
 
 

April 1

st

, 2010 

Renesas Electronics Corporation 

 

 
 
 
 

Issued by: 

Renesas Electronics Corporation

 (

http://www.renesas.com

Send any inquiries to 

http://www.renesas.com/inquiry

 

Summary of Contents for H8/3802

Page 1: ...ok over all the business of both companies Therefore although the old company name remains in this document it is a valid Renesas Electronics document We appreciate your understanding Renesas Electron...

Page 2: ...t for an application categorized as Specific or for which the product is not intended where you have failed to obtain the prior written consent of Renesas Electronics The quality grade of each Renesas...

Page 3: ...FP 64A User System Interface Cable for E6000 Emulator User s Manual User s Manual Rev 3 0 2003 12 H8 3802 HS3802ECH61HE Renesas Microcomputer Development Environment System H8 Family H8 300L Super Low...

Page 4: ...described here may contain technical inaccuracies or typographical errors Renesas Technology Corp assumes no responsibility for any damage liability or other loss rising from these inaccuracies or err...

Page 5: ...system interface cable must only be used for the above purpose Improvement Policy Renesas Technology Corp including its subsidiaries hereafter collectively referred to as Renesas pursues a policy of c...

Page 6: ...rom you Renesas is not liable for any claim made by a third party or made by you for a third party DISCLAIMER RENESAS MAKES NO WARRANTIES EITHER EXPRESS OR IMPLIED ORAL OR WRITTEN EXCEPT AS PROVIDED H...

Page 7: ...t may be reproduced or duplicated in any form in hard copy or machine readable form by any means available without Renesas s prior written consent Other Important Things to Keep in Mind 1 Circuitry an...

Page 8: ...low this symbol to avoid possible injury or death DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a pote...

Page 9: ...in PERSONAL INJURY The USER PROGRAM will be LOST 1 Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance 2 Always switch OFF the E6000 emulator...

Page 10: ...s original microcomputer H8 3802 H8 38004 group The HS3802ECH61H is a user system interface cable that connects an H8 3802 H8 38004 group E6000 emulator HS3800EPI60H hereinafter referred to as the emu...

Page 11: ...IC Socket 5 2 2 2 Soldering IC Socket 5 2 2 3 Inserting Cable Head 6 2 2 4 Fastening Cable Head 6 2 2 5 Fastening Cable Body 8 2 3 Recommended Dimensions for User System Mount Pad 9 2 4 Dimensions for...

Page 12: ...the user system Figure 1 shows the configuration of the HS3802ECH61H user system interface cable for the FP 64A package User system IC socket Cable head To emulator station Cable body Screws M2 x 12...

Page 13: ...tity Remarks 1 Cable body 1 Flat cable 2 Cable head 1 3 IC socket 1 For the FP 64A package 4 Socket cover 1 For installing an FP 64A packaged MCU 5 Screws M2 x 12 mm 4 For fastening cable head with fo...

Page 14: ...make sure that pin 1 on both sides are correctly aligned 2 The user system interface cable dedicated to the emulator must be used To connect the cable body to the emulator station follow the instructi...

Page 15: ...4 Emulator station Cable body connector User system interface cable E 6 0 0 0 Figure 2 Connecting User System Interface Cable to Emulator Station...

Page 16: ...esult in PERSONAL INJURY The USER PROGRAM will be LOST To connect the cable head to the user system follow the instructions below 2 2 1 Installing IC Socket After checking the location of pin 1 on the...

Page 17: ...rewdriver whose head matches the screw head 2 The tightening torque must be 0 098 N m or less If the applied torque cannot be accurately measured stop tightening when the force required to turn the sc...

Page 18: ...rnating between screws on opposing corners Take special care such as manually securing the IC socket soldered area to prevent the soldered IC socket from being damaged by overtightening the screws or...

Page 19: ...8 2 2 5 Fastening Cable Body Connect the cable body to the cable head Cable body Cable head Remove jig Push the remove jigs Removing User system Figure 4 Fastening Cable Body...

Page 20: ...an IC socket for an FP 64A package IC149 064 008 B5 manufactured by YAMAICHI ELECTRONICS Co Ltd Note that the dimensions in figure 5 are somewhat different from those of the actual chip s mount pad U...

Page 21: ...User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6 Unit mm Tolerance 0 5 mm 63 5 58 4 17 8 28 0 15 2 28 0 Figure 6 Dimensions for User Syste...

Page 22: ...after connecting the user system interface cable head to the user system are shown in figure 7 IC socket IC149 064 008 B5 manufactured by YAMAICHI ELECTRONICS Co Ltd 14 0 21 5 Cable head User system U...

Page 23: ...w head may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MCU does not operate correctly cracks might have occurred in the solder Check conduction with a...

Page 24: ...13 MCU Pin 1 IC socket IC149 064 008 B5 manufactured by YAMAICHI ELECTRONICS Co Ltd User system Screws M2 x 8 mm with flat washers Socket cover Figure 8 Installing MCU to User System...

Page 25: ...y the external clock from the user system to the emulator by inputting the external clock from the OSC1 terminal on the cable head or connecting a crystal oscillator to the OSC1 and OSC2 terminals Whe...

Page 26: ...cable and the subclock input specifications R2 270 R1 1 M HCU04 HCU04 To E6000 emulator OSC1 OSC2 System clock oscillator 4 0 V 19 ns max 19 ns max 4 0 V 1 35 V 0 V 5 0 V 1 35 V Subclock input specifi...

Page 27: ...cable body do not place heavy or sharp metal objects on the user system interface cable 5 While the emulator station is connected to the user system with the user system interface cable force must not...

Page 28: ...17 P1 3 1 Figure 11 P1 Short Connector...

Page 29: ...Manual Publication Date Rev 3 00 December 19 2003 Published by Sales Strategic Planning Div Renesas Technology Corp Edited by Technical Documentation Information Department Renesas Kodaira Semiconduct...

Page 30: ...1753 Shimonumabe Nakahara ku Kawasaki shi Kanagawa 211 8668 Japan H8 3802 Group FP 64A User System Interface Cable for E6000 Emulator REJ10B0098 0300H User s Manual...

Reviews: