1 Features
7
1.3.2 Trace Condition Setting
The following designations are available as trace events:
•
Address designation
-
Instruction fetch
-
Memory access
-
Bit access
•
External trigger designation (eight events)
•
Interruption
The number of events that can be specified are six events of all. These break events can be combined
as below:
•
Trace when all of the valid events are established (AND condition)
•
Trace when all of the valid events are established at the same time (And(same time) comdition)
•
Trace when one of the valid events is established (OR condition)
•
Trace upon entering a break state during state transition (State Transition condition)
You can select "specified task only" (or "other than specified task") as the trace condition to meet the
real time OS.
1.3.3 Trace Data Write Condition
Trace data write conditions can be specified.
You can specify the following write conditions:
•
Write conditions unlimited (default)
•
Cycles from the start event established to the end event established
•
Only cycles where the start event is established
•
Cycles from the start event established to the start event unestablished
•
Other than cycles from the start event established to the end event established
•
Other than cycles where the start event is established
•
Other than cycles from the start event established to the start event unestablished
Summary of Contents for Emulator Debugger M16C PC4701
Page 13: ...Setup of Debugger 1...
Page 14: ...Blank Page 2...
Page 73: ...Tutorial 59...
Page 74: ...Blank Page 60...
Page 95: ...Reference 81...
Page 96: ...Blank Page 82...
Page 128: ...Example Writing byte length data 32h to even address 400h 114...
Page 130: ...16 bits bus width 116...
Page 132: ...2nd point 118...
Page 133: ...7 Windows Dialogs 16 bits bus width 119...
Page 134: ...Example Writing data 10h 3Fh to even address 400h 120...
Page 138: ...Example Writing byte length data 32h to even address 400h 124...
Page 140: ...16 bits bus width 126...
Page 141: ...7 Windows Dialogs Example Writing word length data 1234h to even address 400h 127...
Page 142: ...Example Writing data 10h 3Fh to even address 400h 128...
Page 146: ...Example Writing byte length data 32h to even address 400h 132...
Page 147: ...7 Windows Dialogs Example Writing data 10h 3Fh to even address 400h 133...
Page 153: ...7 Windows Dialogs 7 7 8 2 Interrupt Termination Set as below 139...
Page 172: ...For condition 7 choose the Mode shown below and set the Start event 158...
Page 294: ...MEMO 280...