Rendamax R3456 EVO Manual Download Page 35

Accessories

 

 

 
 
 
 

System selection  

 

The R3456 EVO is supplied from the 

factory  with LMS14 boiler management 

unit. Additional a wide variation of 

accessory kits is available. The 

accessory kits are specially designed for 

the R3456 EVO and are very easy to 

combine with the boiler to create a 

complete system solution. 
 
 

The plug & play accessory kits 

enable a very easy selection and 

assembly of a complete system 

solution. As the kits can be 

combined very easily, a wide 

variation of solutions can be made 

by just picking the right kits from 

the selection table. The accessory 

kits are pre-assembled and can be 

mounted to the boiler very quickly. 

The accessory kits are built in a 

modular way. The kits are listed 

on the next pages. 

34 

System selection 

Summary of Contents for R3456 EVO

Page 1: ...Planner Documentation R3456 EVO 06 2020...

Page 2: ......

Page 3: ...Water quality 21 Noise protection 22 Antifreeze 22 Flue gas system Requirements and regulations 23 Materials 23 Flue gas data 24 Dimensioning 25 Neutralisation General 26 Neutralisation systems 26 Sta...

Page 4: ...QAC34 41 Extension module AVS75 41 Commercial Gateway 41 Gas filter 41 Web server OZW672 01 16 41 Gas pressure regulator 300mbar connection kit 42 Air filter 42 Disassembly set 42 Gas flue damper 42...

Page 5: ...can cover installations up to 32 MW Preferred applications are central heating and sanitary hot water production in hospitals municipal sport facilities industrial and educational buildings Value pro...

Page 6: ...ection where is the lowest flue gas tempera ture in the boiler In this section con densation takes place The water is being transported upwards through the boiler leaving the boiler at the top burner...

Page 7: ...40 30 C max min C 167 65 Flue gas quantity max min m3 h 1438 286 1606 318 1878 372 2126 422 2374 471 CO2 level main burner G20 G25 max min 10 0 9 3 CO2 level main burner G31 max min 11 0 11 0 CO2 leve...

Page 8: ...0 C max min C 167 65 Flue gas quantity max min m3 h 2619 519 2867 568 3277 649 3685 730 4095 811 CO2 level main burner G20 G25 max min 10 0 9 3 CO2 level main burner G31 max min 11 0 11 0 CO2 level pi...

Page 9: ...max min C 134 64 Flue gas quantity max min m3 h 1252 303 1465 353 1659 400 1852 447 2044 493 CO2 level main burner G20 G25 max min 10 0 9 3 CO2 level main burner G31 max min 11 0 11 0 CO2 level pilot...

Page 10: ...64 Flue gas quantity max min m3 h 2236 539 2556 616 2874 692 3194 770 CO2 level main burner G20 G25 max min 10 0 9 3 CO2 level main burner G31 max min 11 0 11 0 CO2 level pilot burner G20 G25 max min...

Page 11: ...51 32 Flue gas quantity max min m3 h 1005 297 1176 346 1332 393 1487 439 1641 485 CO2 level main burner G20 G25 max min 10 0 9 3 CO2 level main burner G31 max min 11 0 11 0 CO2 level pilot burner G20...

Page 12: ...C max min C 51 32 54 32 Flue gas quantity max min m3 h 1795 529 2052 605 2307 680 2565 756 3115 795 CO2 level main burner G20 G25 max min 10 0 9 3 CO2 level main burner G31 max min 11 0 11 0 CO2 leve...

Page 13: ...660 660 660 660 660 660 660 660 660 H3 mm 540 530 530 530 530 530 530 530 530 530 530 H4 mm 480 480 500 500 500 500 460 460 480 480 480 Dimen sions B mm 1370 1370 1170 1170 1370 1370 1370 1170 1170 1...

Page 14: ...L3 mm 350 350 L4 mm 230 230 L5 mm 710 710 LW mm 185 185 H mm 1555 1575 H1 mm 895 915 H2 mm 420 435 H3 mm 470 490 H4 mm 240 260 Dimensions B mm 1570 1370 B1 mm 1445 1250 B2 mm 785 685 B3 mm 145 145 B4...

Page 15: ...50 L3 mm 350 350 L4 mm 150 150 L5 mm 710 710 LW mm 185 185 H mm 1575 1575 H1 mm 915 915 H2 mm 440 440 H3 mm 490 490 H4 mm 260 260 Dimensions B mm 1570 1570 B1 mm 190 140 B2 mm 785 785 B3 mm 195 145 B4...

Page 16: ...0 450 500 500 500 W DN DN80 PN16 DN80 PN16 DN80 PN16 DN80 PN16 DN80 PN16 G DN DN65 PN16 DN65 PN16 DN80 PN16 DN80 PN16 DN80 PN16 Dimensions L mm 2795 3310 3310 3310 3310 L1 mm 480 480 480 480 480 L2 mm...

Page 17: ...5502 2 1 EN 55014 1 2 EN 61000 3 2 3 EN 60 335 1 2 And in accordance with the guidelines of directives 92 42 EEC boiler efficiency directive 2009 142 EEC gas appliance directive 2014 35 EU low voltage...

Page 18: ...Syphon dirt seperator for condensate connection 1 Cardboard box on top of heat exchanger under casing Operation and Installation manual 1 On inside of front panel Boiler transport Whenever necessary...

Page 19: ...Extent of delivery Component Dimensions R3400 3500 3600 EVO 18 R3401...

Page 20: ...Extent of delivery Component Dimensions R3400 3500 3600 EVO 19 EVO...

Page 21: ...ces Safety Part 1 General requirements EN 60335 2 102 Household and similar appliances Safety Part 2 102 Particular requirements for gas oil and solid fuel burning appliances having electrical connect...

Page 22: ...ed with water with a PH value between 7 0 and 9 5 The chloride sulphide and nitride value of the water should not exceed 50 mg l Entry of oxygene by diffusion should be prevented at all times Damage t...

Page 23: ...n The relation between antifreeze concentration and capacity reduction of the boiler can be found in the graph The maximum percentage of antifreeze should not exceed 30 The R3456 EVO is supplied with...

Page 24: ...onal external safety device is not necessary Plastic PP Stainless steel Temperature class T120 T250 Pressure class P1 Corrosion class W1 W1 The installer is responsible to apply the correct diameter l...

Page 25: ...2 288 3 89 9 R3502 EVO 719 204 764 218 350 1 337 3 104 8 R3503 EVO 814 231 865 247 400 1 381 9 118 8 R3504 EVO 909 258 966 276 400 1 426 5 132 7 R3505 EVO 1003 285 1066 305 400 1 470 7 146 7 R3506 EV...

Page 26: ...ways longer than 20m a faultless burner start in cold condition can not be guaranteed 25 Maximum permissible height h of flue gas system in m Type 250mm 300mm 350mm 400mm 450mm 500mm R3401 EVO 23 50...

Page 27: ...tems can be placed in the bottom section of the boiler The delivery of the system contains the following components Granulate for first filling Connection hoses for inlet and outlet connection Boiler...

Page 28: ...on 100 load An indication of the actual flow rate can be found with the following calculation see table below for nominal data p measurement Check the pressure difference over the boiler p flow return...

Page 29: ...ominal flow rate m3 h 26 4 30 9 35 0 39 1 43 1 47 2 53 9 60 7 67 4 T at nominal flow rate K 20 p at nominal flow rate kPa 37 25 30 35 40 60 72 93 114 1 0 10 0 100 0 8 0 80 0 P r e s s u r e d r o p k...

Page 30: ...VO R3604 EVO R3605 EVO R3606 EVO R3607EVO R3608 EVO R3609 EVO R3610 EVO R3600 EVO R3601 EVO R3602 EVO R3603 EVO R3604 EVO R3605 EVO R3606 EVO R3607 EVO R3608 EVO R3609 EVO R3610 EVO Nominal flow rate...

Page 31: ...p modulates the flow rate in the primary system in parallel with the burner load This ensures the lowest possible return temperature to the boiler for high efficiency usage Details of the available pu...

Page 32: ...ignal Boiler enable signal 0 10VDC temperature or capacity setpoint programmable 0 10VDC capacity feedback Temperature control central heating via PID controller Temperature control sanitary hot water...

Page 33: ...ales 29 common 30 Alarm 31 ok potential free Run Signal terminals 32 common 33 ON 34 OFF potential free Capacity feedback signal terminals 120 121 0 10VDC This signal is available at the mentioned ter...

Page 34: ...gon B G2Z2 controller in a wall hung box is available These kits can be used in a modular way up to a maximum of 8 heating zones See chapter Installation examples for more details regarding connection...

Page 35: ...ler to create a complete system solution The plug play accessory kits enable a very easy selection and assembly of a complete system solution As the kits can be combined very easily a wide variation o...

Page 36: ...ction point for the high limit thermostat on the boiler flow pipe The high limit thermostat is electrical ly wired and can be connected direct ly to the terminals in the boiler Con sult the supplied i...

Page 37: ...5 3 231 1 71 5 130 0 R3410 EVO 158 9 660 0 105 9 293 3 79 4 165 0 R3501 EVO 52 9 148 0 35 3 65 8 26 5 37 0 R3502 EVO 61 9 100 0 41 3 44 4 31 0 25 0 R3503 EVO 70 1 120 0 46 7 53 3 35 1 30 0 R3504 EVO 7...

Page 38: ...variation of positioning pos sibilities The connections have to be made on site Insulation for the mono and duo headers is available as accessory Accessories Hydraulics 37 A Diameter DN 150 150 200 2...

Page 39: ...0 2400 C Height to boiler return mm 630 630 630 1065 D Boiler flow return distance mm 1080 1080 1080 994 E Header body height mm 2270 2270 2270 2270 F Height to system return mm 310 310 310 568 G Syst...

Page 40: ...he system Bypass The kit includes a bypass pump including connection material The kit is to be connected between the flow and 2nd return connection of the boiler The bypass pump is electrically wired...

Page 41: ...s room units QAA78 and or wireless outdoor sensors QAC34 AVS13 OUTDOOR SENSOR AVS13 399 201 WIRELESS The kit contains an outdoor sensor QAC34 and a wireless transmitter AVS13 The kit can be used in co...

Page 42: ...AVS75 390 101 TR XXL The kit contains an AVS75 extension module incl communication cable to the LMS14 boiler management unit Maximum 2 AVS75 modules can be connected to one boiler Commercial Gateway...

Page 43: ...gas filter which can be connected directly to the gas pipe of the boiler Gas pressure regulator 300mbar connection kit The kit contains a gas pressure regulator which can be connected directly to the...

Page 44: ...01 EVO DN65 PN16 26 5 37 0 TP65 120 R3502 EVO DN80 PN16 31 0 25 0 TP80 120 R3503 EVO 35 1 30 0 TP80 120 R3504 EVO 39 2 35 0 TP80 120 R3505 EVO 43 2 40 0 TP80 120 R3506 EVO 47 3 60 0 TP80 170 4 R3507 E...

Page 45: ...0 4 R3601 EVO DN65 PN16 27 5 74 0 MAGNA3 80 120 F R3602 EVO DN80 PN16 32 2 40 0 MAGNA3 80 120 F R3603 EVO 36 4 45 0 MAGNA3 80 120 F R3604 EVO 40 7 67 0 MAGNA3 80 120 F R3605 EVO 44 9 78 0 TPE2 80 180...

Page 46: ...Accessories Standard pumps performance curves 45 Standard pumps performance curves...

Page 47: ...Accessories Standard pumps performance curves 46...

Page 48: ...Accessories Standard pumps performance curves Bypass pumps performance curves Bypass pumps performance curves 47...

Page 49: ...Accessories Bypass pumps performance curves Speed control pumps performance curves Speed control pumps performance curves 48...

Page 50: ...Accessories Speed control pumps performance curves 49...

Page 51: ...Accessories Speed control pumps performance curves 50...

Page 52: ...Accessories Speed control pumps performance curves 51...

Page 53: ...hould be positioned close to the boiler to avoid a nega tive influence on the temperature control quality In case of a boiler room installed on the roof the boiler may never be hydraulically connected...

Page 54: ...uld be taken into consideration during the design stage The header should be positioned close to the boiler to avoid a nega tive influence on the temperature control quality In case of a boiler room i...

Page 55: ...ng the design stage The header should be positioned close to the boiler to avoid a nega tive influence on the temperature control quality In case of a boiler room installed on the roof the boiler may...

Page 56: ...be taken into consideration during the design stage The header should be positioned close to the boiler to avoid a nega tive influence on the temperature control quality In case of a boiler room insta...

Page 57: ...he design stage The header should be positioned close to the boiler to avoid a nega tive influence on the temperature control quality In case of a boiler room installed on the roof the boiler may neve...

Page 58: ...on during the design stage The plate heat exchanger should be positioned close to the boiler to avoid a negative influence on the temperature control quality In case of a boiler room installed on the...

Page 59: ...hould be taken into consideration during the design stage The header should be positioned close to the boiler to avoid a nega tive influence on the temperature control quality In case of a boiler room...

Page 60: ...ng zone control can be extended up to 15 heating zones M T T M T T HC1 HC2 P Logon B B1 B1 B1 59 Non return valve Flow return temperature sensor Inlet valve Common flow temperature sensor Outdoor sens...

Page 61: ...6 1410 9 1568 0 Nominal heat output at 40 30 C kW 625 4 731 8 828 5 925 2 1021 0 1116 8 1276 7 1435 7 1595 7 Efficiency at 80 60 C full load 94 1 94 1 94 1 94 1 94 1 94 1 94 1 94 1 94 1 Efficiency at...

Page 62: ...mbustion efficiency direct at 40 30 C full load 93 5 93 5 93 5 93 5 93 5 93 5 93 5 93 5 93 5 93 5 Combustion efficiency direct at 40 30 C 30 load 103 9 103 9 103 9 103 9 103 9 103 9 103 9 103 9 103 9...

Page 63: ...4 Combustion efficiency direct at 40 30 C full load 95 8 95 8 95 8 95 8 95 8 95 8 95 8 95 8 95 8 Combustion efficiency direct at 40 30 C 30 load 104 1 104 1 104 1 104 1 104 1 104 1 104 1 104 1 104 1 T...

Page 64: ...mbustion efficiency direct at 40 30 C full load 104 5 104 5 104 5 104 5 104 5 104 5 104 5 104 5 104 5 104 4 Combustion efficiency direct at 40 30 C 30 load 109 7 109 7 109 7 109 7 109 7 109 7 109 7 10...

Page 65: ...100 100 100 100 100 100 Operating temperature boiler min C 5 5 5 5 5 5 5 5 5 5 Nominal water flow at dT 20K m3 h 28 0 31 0 36 0 41 0 46 0 51 0 56 0 64 0 72 0 80 0 R3500 EVO R3501 EVO R3502 EVO R3503...

Page 66: ...ll losses dT 30K Twater 50 C Tamb 20 C W n a n a n a n a n a n a n a n a n a n a Loss on surface casing 0 10 0 10 0 10 0 10 0 10 0 10 0 10 0 10 0 10 0 10 Power consumption boiler max excl pump W 900 0...

Page 67: ...4 23 28 32 37 58 38 83 106 UK specific data R3500 EVO R3501 EVO R3502 EVO R3503 EVO R3504 EVO R3505 EVO R3506 EVO R3507 EVO R3508 EVO R3509 EVO Efficiency at 80 60 C full load Gross 84 8 84 8 84 8 84...

Page 68: ...nnual emissions mg kWh 20 20 20 20 20 20 20 20 20 20 BREEAM credits 2014 UK 3 3 3 3 3 3 3 3 3 3 BREEAM credits 2018 UK 2 2 2 2 2 2 2 2 2 2 Nominal water flow at dT 10K m3 h 54 0 64 0 72 0 82 0 90 0 98...

Page 69: ...ichtung von Niederdruck Gasanlagen G2 Techn Richtlinie f r die Errichtung von Fl ssiggasanlagen G41 Gasbrennwert Feuerungsst tten Aufstellung und Anschluss G4 Heizraumrichtlinie Der R3456 EVO ist zuge...

Page 70: ...66...

Page 71: ......

Page 72: ...Service www rendamax com...

Reviews: