Operation
Installation and Start-up
35
Remote controls
The operator module BM 8
(Only for controller models with
CAN-Bus connection)
Electrical connection: Connector IX; 1-4
The E6 permits connection of an
operation-control module BM for each
heating circuit via a bus line. The
operation-control module allows various
operation-control functions and
monitoring functions for the system
values to be relocated to the main
controlled zone - i.e. the living room.
This achieves maximum comfort and
convenience. Please refer to the
technical description of the BM for a
precise description of the overall scope
of functions.
-
Display of the system parameters
-
Entry of the heating circuit
parameters
-
Room temperature control
-
Automatic adaptation of the heat
slope
Remote control FBR 2
Electrical connection: Connector I; 1-3
and connector III; 1-3
-
Rotating switch for modifying room
temperature
setting
Adjusting range: (±5 K)
-
Room control via the integrated
room
sensor
- Rotating
switch
for
selecting
operating
mode
i
Standby/OFF (frost protection only)
q
Automatic mode (according to
timer program 1 in controller)
q
Automatic mode (according to
timer program 2 in controller)
C
24-hour night operation (reduction
temperature)
B
24-hour daytime operation (comfort
temperature)
F
Summer mode (heating OFF, hot
water only)
!
The heating program switch at the
controller must be set to
q
.