background image

 

 

 

 

 

+

+

Ø

32

Ø

38mm

~

Strip length 12mm 

PE
N(

three-wise without

L1
L2
L3

Ø

5

Ø

8mm

~

 

+
-

 

Solar Inverter

1.Unpack And Check

Notice 

2.Inverter Fixation

   In any case, this guidance is not intended to replace the user manual or 
safety instructions of the product.
   Make sure that you have read completely and understand fully, and 
carefully follow the user's manual and relevant specifications before any 
operation.
   Otherwise, it will result in casualties and equipment damage.

1) Unpack and take out inverter and accessories.
2)  Please  check  if  model  of  received  inverter  is  correct  and  items  listed  in 
packing list are all included.
3)  Please  contact  your  local  distributor  if  the  inverter  is  found  damaged  or 

accessories found not comply with packing list, don't try to install it.

1)  Please  refer  to  inverter  user  manual  to  select  proper  position  to  install 
the inverter. Keep enough space for heat-dissipation when there are a few 
inverters to be installed, at least 1.0m for  inverter.
2) Pay attention to human and inverter safety when moving the inverters.

3) Inverter must be placed vertically, not allowed to flat, tilt or inverted.
4) Follow the steps below to fix the inverter.

2.1Fix the rack on the metal holder. (standard: M10*35mm, nut and flat pad)

 

Drill

 

hole

 

can

 

be

 

reserved

 

or

 

drilled

 

on

 

site

 

on

 

the

 

metal

 

holder

 

according

 

to

 

the

 

hole

 

size

 

of

 

rack

,

drill

 

hole

 

size

 

should

 

be

 

Ø12mm, as precise as possible.

 

Drill

 

hole

 

can

 

be

 

reserved

 

or

 

drilled

 

on

 

site

 

on

 

the

 

metal

 

holder

 

according

 

to

 

the

 

hole

 

size

 

of

 

rack

,

drill

 

hole

 

size

 

should

 

be

 

Ø12mm, as precise as possible.

2.2 The installation rack is fixed on the wall. (optional:M10*60mm,expansion

 

bolt).

 

Fix  the  installation  rack  contained  in  the  package  on  the  wall  horizontally, 

drill  hole  according  to  rack,  drilling  tool  adoptsØ14mm  impact,  depth  should 
be more than 70mm, position should be as accurate as possible.

 

Clear  dust  inside  and  outside  the  hole,  insert  an  expansion  pipe  vertically 

into the hole, use hammer to knock until it is in the hole entirely, then unscrew 
the bolt, then fix and tighten the rack on the wall with the bolt.

2.3 Hang the inverter gently up and hung on the rack, check and ensure that 
both  sides  are  fixed  in  the  correct  position,  then  tighten  the  screws  at  both 
ends (attached in accessoriesbag).

2.4 Hang the inverter on the screws, check right and left sides, make sure the 
it is hung in the right position, then screw the screws tight.

3.Electric Connection

Danger

High voltage is present inside inverter it may do harm to human safety.
Before doing connection, make sure there are not power present in DC 
and AC cables.

Warning

+ and - of PV are not allow to be grounded, otherwise the inverter may 
be damaged Recommended open circuit voltage of PV array.
Before finishing connections, DON'T switch on DC and AC breaker.

R e c o m m e n d t h e P V a r r a y o p e n - c i r c u i t v o l t a g e ( 2 5 ° C ) . 

7 0 0 . . . 8 5 0 V

3.1 Ac Cable

10-16mm²

Terminal

AC terminal

DC terminal

Ground protection terminal

4-6mm²

35-50mm² 

Sectional area range of conductor Recommendation(copper)

4mm²

50mm²

10mm²

AC

 

Cable

DC

 

Cable

3.2 AC Cable Connection

 

First remove the lower cover of the inverter with an L-type spanner(in 

the accessory bag).

 

make the inverter output cable go through water proof sleeves of AC 

output  cover,  5  (or  4)  cores  cable  are  crimped  on  the  terminal  (in  the 
accessory bag) and heat shrinkable casing respectively for protection.

 

connect the 5 cores to inverter output terminals L1,L2,L3,N, and PE 

separately(three-wise  system  do  not  have  “N”  wise),  Use  straight 
screwdriver  to  tighten  it.  The  AC  output  is  three  phase,  mode  of 
connection should be L1/L2/L3+N+PE or L1/L2/L3+PE. Finally, lock the 
lower cover.

The example below is four-wise system.

Note: 

while connecting, the switch of AC side must be open, otherwise 

it will do harm to the human body; it should use professional crimping 
tool  while  crimping  terminal,  make  sure  the  crimping  is  well,  and 
ensure safety.

Strip length 7mm 

400mm

2

2

0

m

m

1

2

L1 L2 L3

PE

N

NAC70K, NAC80K

Quick Installation  Manual