6.6 Installation steps
Step 1:
Screw the wall bracket on the wall
Use the wall bracket as a template to mark the position of the 4 holes.
Drill holes with ф10 driller carefully, make sure the holes are deep enough (at least 45mm)
for install and tight the expansion tubes.
Install the expansion tubes in the holes, and tight them. Install the wall bracket using the
expansion screws in the screw package.
Step 2:
Hang the ESC-Hybrid Inverter on the wall bracket.
Transportation of the inverter needs at least 2 people, each one needs to use the handles at
the sides of the inverter.
Hang the inverter over the bracket, move the inverter close to it, slightly laydown the inverter
make sure the 4 mounting bars on the back of the inverter is fixed well with 4 grooves on the
bracket.