![Renac ESC3000-DS Manual Download Page 13](http://html1.mh-extra.com/html/renac/esc3000-ds/esc3000-ds_manual_1439510013.webp)
13
EPS Rated Power
3000W
EPS Rated Voltage
220V/230V
EPS Rated Frequancy
50/60HZ
EPS Rated Current
13A
Output THDi(@Rated Output)
<3%
Automatic switch time
<5s
Peak power , Duration
4500W, 10S
Efficiency
Max.Efficiency
97.60%
97.60%
97.60%
Euro Effciency
97.00%
97.00%
97.00%
MPPT Effciency
99.90%
99.90%
99.90%
Battery Charge/Discharge efficiency
94.00%
94.00%
94.00%
Protection
DC Insulation Monitoring
Intergrated
Input Reverse Polarity Protection
Intergrated
Anti-island Protection
Intergrated
Residual Current Monitoring
Intergrated
Over-heat Protection
Intergrated
AC Overcurrent Protection
Intergrated
AC Short-circuit Protection
Intergrated
AC Overvoltage Protection
Intergrated
DC Surge Protection
Integrated(Type III)
AC Surge Protection
Integrated(Type III)
General Data
Size(Width*Height*Depth)
526*528*193mm
Weight
29.5KG
User Interface
LCD
Communication
Ethernet(standard), RS485 or Wifi or GPRS
Ambient Temperature Range
-25
℃
~ 60
℃
Relative Humidity
0-100%
Operating Altitude
≤4000m
Standby Self Consumption
<1W
Topology
Transformerless
Cooling
Natural Convection
Protection Grades
IP65
Noise
<35db
Warranty
5 /7/10 years
Certifications & Standards
Grid Regulation
G98,G99,NRS-097 MEA, PEA, AS4777,EN50438,CEI-
021
Safety Regulation
IEC 62109-1, IEC 62109-2,IEC62040
EMC
EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN
61000-6-4, EN 61000-4-16, EN 61000-4-18, EN
61000-4-29