1.6 Safety instructions for the oper-
ator
The operational safety of the units and compo-
nents is only assured providing they are used as
intended and in a fully assembled state.
n
The units and components may only be set up,
installed and maintained by qualified per-
sonnel.
n
Protective covers (grills) over moving parts
must not be removed from units that are in
operation.
n
Do not operate units or components with
obvious defects or signs of damage.
n
Contact with equipment parts or components
can lead to burns or injury.
n
The units and components must not be
exposed to any mechanical load, extreme
levels of humidity or extreme temperatures.
n
All housing parts and unit openings, e.g. air
inlets and outlets, must be free from foreign
objects, fluids or gases.
n
The units must be inspected by a service tech-
nician to ensure that they are safe to use and
fully functional at least once yearly.
1.7 Safety notes for
installation, maintenance and
inspection
n
Appropriate hazard prevention measures must
be taken to prevent risks to people when per-
forming installation, repair, maintenance or
cleaning work on the units.
n
The setup, connection and operation of the
units and its components must be undertaken
in accordance with the usage and operating
conditions stipulated in this manual and comply
with all applicable regional regulations.
n
The electrical power supply should be adapted
to the requirements of the units.
n
Units may only be mounted at the points pro-
vided for this purpose at the factory.
n
Observe the minimum clearances.
n
The units and components must be kept at an
adequate distance from flammable, explosive,
combustible, abrasive and dirty areas or
atmospheres.
n
Safety devices may not be modified or
bypassed.
1.8 Unauthorised modification
and changes
Modifications or changes to units and components
are not permitted and may cause malfunctions.
Safety devices may not be modified or bypassed.
Original replacement parts and accessories
authorised by the manufactured ensure safety. The
use of other parts may invalidate liability for
resulting consequences.
1.9 Intended use
The heater for anti-freeze protection is used to
control the temperature of the interior space of the
hydraulic module. This ensures that in the event of
a fault, the last step in the freezing of the medium
and thus defects due to frost can be prevented. A
temperature of >+3 °C is established through recir-
culated air operation. It is essential that a separate
UPS is used for the power supply.
Any different or additional use is a non-intended
use. The manufacturer/supplier assumes no lia-
bility for damages arising from non-intended use.
The user bears the sole risk in such cases.
Intended use also includes working in accordance
with the operating and installation instructions and
complying with the maintenance requirements.
The threshold values specified in the technical
data must not be exceeded.
1.10 Warranty
For warranty claims to be considered, it is essential
that the ordering party or its representative com-
plete and return the "certificate of warranty" to
REMKO GmbH & Co. KG at the time when the
units are purchased and commissioned.
The warranty conditions are detailed in the "Gen-
eral business and delivery conditions". Further-
more, only the parties to a contract can conclude
special agreements beyond these conditions. In
this case, contact your contractual partner in the
first instance.
1.11 Transportation and pack-
aging
The units are shipped in sturdy transport pack-
aging or within the heat pump housing. Immedi-
ately check the units on delivery and make a note
of any damage or missing parts on the delivery
note. Inform the forwarding agent and contractual
partner. Claims under guarantee made at a later
date will not be accepted.