2
Technical data
2.1
Unit data
Series
RVT 262
RVT 352
RVT 522
RVT 682
Operating mode
Inverter wall-mounted room air conditioner combination for
cooling and heating
Nominal heat capacity
2)
kW
3,11
(1,00-4,10)
3,71
(1,00-4,60)
5,28
(1,60-6,30)
7,30
(2,90-8,40)
Energy efficiency ratio SCOP
4)
4,0
4,0
3,9
3,8
Rated elec. pwr consum. heat.
2)
kW
0,74
0,90
1,25
2,03
Rated elec. curr. consum. heat.
2)
A
3,24
3,94
5,43
8,80
Power consump., annual, Q
HE
3)
kWh
1050
1295
1867
2395
Energy efficiency ratio, heat.
2)
A+
A+
A
A
Nominal cooling output
1)
kW
2,92
(1,10-3,70)
3,81
(1,10-4,20)
5,20
(1,60- 6,30)
6,80
(3,20-7,60)
Energy efficiency size SEER
1)
7,0
6,3
6,9
5,8
Rated elec. pwr consum. cool.
1)
kW
0,72
1,51
1,67
2,45
Rated elec. curr. consum. cool.
1)
A
3,14
6,59
7,27
10,60
Power consump., annual, Q
CE
3)
kWh
145
206
259
453
Energy efficiency ratio, cooling
1)
A++
A++
A++
A+
Max. power consumption
kW
2,10
2,10
2,85
3,60
Max. current consumption
A
9,50
9,50
13,00
16,50
EDP no.
1623104
1623114
1623124
1623134
Data specific to indoor unit IT
RVT 262
RVT 352
RVT 522
RVT 682
Approx. application area
m
3
80
110
160
230
Adjustment range, room temp.
°C
+17 bis +30 +8 with "FP"-function
Operating range
°C
+17 to +32
Air flow volume per level
m³/h
420/570/650 440/580/750 750/900/1150 1050/1280/1450
Sound pressure level per level
5)
dB (A)
28/36/40
32/37/42
33/38/46
42/45/50
Sound pressure level,
Silent/Turbo mode
5)
dB (A)
22/42
23/44
25/48
27/52
Sound power max.
dB(A)
52
56
56
63
Enclosure class
IP
X 0
Condensate drainage connection
mm
18
REMKO RVT-ARCTIC-WP
8
Summary of Contents for RVT 262
Page 66: ...REMKO RVT ARCTIC WP 66...