1.1  General safety notes

Carefully read the operating manual before com-

missioning the units for the first time. It contains

useful tips and notes such as hazard warnings to

prevent personal injury and material damage.

Failure to follow the directions in this manual not

only presents a danger to people, the environment

and the system itself, but will void any claims for

liability.

Keep this operating manual and the refrigerant

data sheet near to the units.

1.2  Identification of notes

This section provides an overview of all important

safety aspects for proper protection of people and

safe and fault-free operation.The instructions and

safety notes contained within this manual must be

observed in order to prevent accidents, personal

injury and material damage.

Notes attached directly to the units must be

observed in their entirety and be kept in a fully

legible condition.

Safety notes in this manual are indicated by sym-

bols. Safety notes are introduced with signal words

which help to highlight the magnitude of the danger

in question.

 DANGER!

Contact with live parts poses an immediate

danger of death due to electric shock. Damage

to the insulation or individual components may

pose a danger of death.

 DANGER!

This combination of symbol and signal word

warns of a situation in which there is immediate

danger, which if not avoided may be fatal or

cause serious injury.

 WARNING!

This combination of symbol and signal word

warns of a potentially hazardous situation,

which if not avoided may be fatal or cause

serious injury.

 CAUTION!

This combination of symbol and signal word

warns of a potentially hazardous situation,

which if not avoided may cause injury or mate-

rial and environmental damage.

 NOTICE!

This combination of symbol and signal word

warns of a potentially hazardous situation,

which if not avoided may cause material and

environmental damage.

This symbol highlights useful tips and recom-

mendations as well as information for efficient

and fault-free operation.

1.3  Personnel qualifications

Personnel responsible for commissioning, opera-

tion, maintenance, inspection and installation must

be able to demonstrate that they hold a qualifica-

tion which proves their ability to undertake the

work.

1.4  Dangers of failure to observe

the safety notes

Failure to observe the safety notes may pose a risk

to people, the environment and the units. Failure to

observe the safety notes may void any claims for

damages.

In particular, failure to observe the safety notes

may pose the following risks:

n

The failure of important unit functions.

n

The failure of prescribed methods of mainte-

nance and repair.

n

Danger to people on account of electrical and

mechanical effects.

1.5  Safety-conscious working

The safety notes contained in this manual, the

existing national regulations concerning accident

prevention as well as any internal company

working, operating and safety regulations must be

observed.

 

 

 

REMKO storage tank systems

 

 

4

Summary of Contents for KPS 130

Page 1: ...perating instructions Read the instructions prior to performing any task REMKO storage tank systems KPS 130 KPS 300 Buffer tanks for hot cold water Instructions for users and specialists 0117 2018 09 Edition 1 en_GB ...

Page 2: ...ig inal Read these operating instructions carefully before commis sioning using this device These instructions are an integral part of the system and must always be kept near or on the device Subject to modifications No liability accepted for errors or mis prints ...

Page 3: ...r 5 1 7 Safety notes for installation and inspection tasks 5 1 8 Unauthorised modification and changes 5 1 9 Intended use 5 1 10 Warranty 5 1 11 Transportation and packaging 6 1 12 Environmental protection and recycling 6 2 Technical data 7 2 1 Unit data 7 2 2 Unit dimensions 7 3 Unit description 8 4 Installation instructions for qualified personnel 8 5 Installation 9 6 Commissioning 12 7 Care and...

Page 4: ...atal or cause serious injury WARNING This combination of symbol and signal word warns of a potentially hazardous situation which if not avoided may be fatal or cause serious injury CAUTION This combination of symbol and signal word warns of a potentially hazardous situation which if not avoided may cause injury or mate rial and environmental damage NOTICE This combination of symbol and signal word...

Page 5: ...or bypassed 1 8 Unauthorised modification and changes The operational safety of the supplied units components is guaranteed when used in line with intended use in accordance with section 1 9 of the operating instructions Under no circumstances should the threshold values specified in the data sheet be exceeded Modifications or changes to units and components are not permitted and may cause malfunc...

Page 6: ... Environmental protection and recycling Disposal of packaging All products are packed for transport in environ mentally friendly materials Make a valuable contri bution to reducing waste and sustaining raw mate rials Only dispose of packaging at approved collection points Disposal of equipment and components Only recyclable materials are used in the manufac ture of the devices and components Help ...

Page 7: ...y consumption value radiation value as per DIN 44532 kWh d 2 2 2 2 We reserve the right to make technical changes in connection with technical advancement 2 2 Unit dimensions 246 983 1514 305 1797 ø600 90 180 1420 5 924 5 1689 ø670 90 A B 85 340 480 742 G1 G1 G1 G1 Fig 1 Unit dimensions all measurements in mm A KPS 130 B KPS 300 We reserve the right to make technical changes in connection with tec...

Page 8: ...nance repairs and even for the possible replacement of the unit e g avoid narrow passageways and doorways n When installing the buffer tanks in non standard locations such as in lofts residential units with floors that are sensitive to water storerooms etc take account of the possibility of leaking water and ensure that a facility is in place to collect the water including appropriate drainage met...

Page 9: ...uxiliary heater must not be used as a permanent heating system Assignment of the connection ports KPS 130 1 3 2 4 5 Fig 2 Assignment of the connection ports KPS 130 1 Inlet heat pump heating cycle 1 AG 2 Optional Auxiliary heater immersion heating 6 4 IG 3 Return flow heat pump heating cycle 1 AG 4 Inlet heat pump heating cycle 1 AG 5 Return flow heat pump heating cycle 1 AG Assignment of the conn...

Page 10: ... valve safety assembly 2 inlet heat pump 5 4 AG 3 immersion tube for temperature sensors 4 return flow heat pump 5 4 AG 5 inlet heating cycle 5 4 AG 6 Optional Auxiliary heater immersion heating 6 4 IG 7 Cleaning flange or opening for fin tube heat exchanger D180 special accessory 8 Heating circuit return flow and drainage through customer provided T section 5 4 AG REMKO storage tank systems 10 ...

Page 11: ...HGU HGM 1 HGM 2 KPS 300 HPU optional A B D 1 2 3 4 C A Outdoor unit s B Indoor unit C Boiler wall heating device D Storage tank 1 Cooling cycle 2 Unmixed heating cycle 3 Mixed heating cycle 1 4 Mixed heating cycle 2 Installation example hydraulic circuit diagram heat pump package WKF Cologne Schema _WKF_Köln_03_oe_g_m__ww_092014 S 08 HGU HGM 1 HGM 2 KPS 300 A B D 1 2 3 4 C A Outdoor unit B Indoor ...

Page 12: ...e n Clean the units with a damp cloth by adding for instance a liquid household cleaner Do not use any caustic abrasive or solvent based cleaning products Maintenance n It is recommended that you take out a mainte nance contract with an annual service from an appropriate specialist firm This enables you to ensure the operational reli ability of the plant at all times n Regularly check the function...

Page 13: ...nd recycling specialists or at collection points REMKO GmbH Co KG or your contractual partner will be pleased to provide a list of certified firms in your area CAUTION During drainage of the storage tank hot water may escape NOTICE When putting the storage tank back into service ensure that it is filled with water and that water which is free of bubbles is escaping from the valves 9 Spare parts li...

Page 14: ... Operating pressure 7 Operating temperature 7 Ordering spare parts 13 R Rated contents 7 S Safety Dangers of failure to observe the safety notes 4 General 4 Identification of notes 4 Instructions for the operator 5 Note for inspection work 5 Note for installation work 5 Personnel qualifications 4 Safety conscious working 4 Unauthorised modification 5 Unauthorised replacement part manufacture 5 Shu...

Page 15: ......

Page 16: ...ct as advisers to our customers in air conditioning and heating technology SFlbCustomer Service Our equipment operates precisely and reliably However in the event of a fault REMKO customer service is quickly at the scene Our comprehensive network of experienced dealers always guarantees quick and reliable service REMKO INTERNATIONAL and also right in your neighbourhood Make use of our experience a...