![REMKO HITLINE LRM 350 Operating And Installation Instructions Download Page 7](http://html1.mh-extra.com/html/remko/hitline-lrm-350/hitline-lrm-350_operating-and-installation-instructions_1438802007.webp)
2
Technical data
2.1 Unit data
Unit data LRM 350
Series
LRM 350
Version
Local air purifier with quadruple filtration
Max. cleaning performance
m
3
/h
300
Filter stages
Nylon pre-filter, filter foam mat, activated carbon
granulate cassette, HEPA H13 filter
HEPA H13 filter separation efficiency
%
99.975
Operating range
°C/r.H.%
+5 to +50/35 to 75
Power supply
V/Ph/Hz
230/1~/50
Enclosure class
IP20
Fan stage
Sleep
1
2
3
Room area application area, per stage
m
2
-
15-20
20-28
28-35
Air flow volume per stage setting
m
3
/h
101
150
210
325
Power consumption, per stage
W
5
8
11
40
Max. current consumption
A
0.04
0.07
0.1
0.29
Sound pressure level, per stage
1)
dB(A)
28
39
45
59
Sound power level, per stage
dB(A)
36
47
53
67
Series
LRM 350
Dimensions
Height
mm
617
Width
mm
400
Depth
mm
190
Weight
kg
6.8
Standard colour
White, similar to RAL 9003
EDP no.
1620350
1)
Distance 1 m free field
We reserve the right to modify the dimensions and design as part of the ongoing technical development
process.
REMKO
7