Operation
√ The controller is in the status display.
You can display and reset the saved minimum/
maximum/difference values as follows:
1.
If necessary, press "
r
s
" to display a dif-
ferent component
4
, component flashes).
2.
Press "SET". The minimum/maximum/differ-
ence values are displayed alternately
5
.
3.
If necessary, press "SET" for 2 seconds to
reset the value that is
currently (!)
displayed
6
.
4.
Press "ESC". The status display is displayed.
5.
Repeat steps 1 to 4 if required.
You can display the status of external compo-
nents as follows:
Press "
r
s
" to display the status of a different
component (
4
).
You can call the setting menu as follows:
Press "SET" for 2 seconds
7
. The setting menu is
displayed.
7
7
7
7
6
6
6
6
Fig. 8: Automatic operating mode - operation
4.3 Setting menu
Overview
The diagram below provides an overview of the
structure of the setting menu.
Domestic hot water
target temp.
Time
SET
the time
Setting
Functions
SET
Heat content
F:01
Thermal
disinfection
Factory setting
Circulation
F:02
SET
5 Sek.
Reset to factory
setting
Distrib. valve in
return flow- F:03
Comfort
function F:04
Bypass
F:05
Follow-up
F:06
Sliding hot water
temp..- F:07
Thermal
disinfection F
:08
Cascade
F:09
Call the setting menu and select the menu
entry
√ "Automatic" or "Off" operating mode is selected.
1.
Press "SET" for two seconds. The setting
menu is displayed, the menu entry flashes.
2.
Press "
r
s
" to select a different menu entry.
3.
Change the settings as described in the fol-
lowing sections.
15