REMKO Easy-Control EC1 Operating And Installation Instructions Download Page 5

1.6  Safety notes for the operator

The operational safety of the units and compo-

nents is only assured providing they are used as

intended and in a fully assembled state.

n

The units and components may only be set up,

installed and maintained by qualified per-

sonnel.

n

Protective covers (grille) over moving parts

must not be removed from units that are in

operation.

n

Do not operate units or components with

obvious defects or signs of damage.

n

Contact with certain unit parts or components

may lead to burns or injury.

n

The units and components must not be

exposed to any mechanical load, extreme

levels of humidity or extreme temperature.

n

Spaces in which refrigerant can leak sufficient

to load and vent. Otherwise there is danger of

suffocation.

n

All housing parts and device openings, e.g. air

inlets and outlets, must be free from foreign

objects, fluids or gases.

n

The units must be inspected by a service tech-

nician at least once annually. Visual inspec-

tions and cleaning may be performed by the

operator when the units are disconnected from

the mains.

1.7  Safety notes for installation,

maintenance and inspection

n

Appropriate hazard prevention measures must

be taken to prevent risks to people when per-

forming installation, repair, maintenance or

cleaning work on the units.

n

The setup, connection and operation of the

units and its components must be undertaken

in accordance with the usage and operating

conditions stipulated in this manual and comply

with all applicable regional regulations.

n

Local regulations and laws such as Water

Ecology Act must be observed.

n

The power supply should be adapted to the

requirements of the units.

n

Units may only be mounted at the points pro-

vided for this purpose at the factory. The units

may only be secured or mounted on stable

structures, walls or floors.

n

Mobile units must be set up securely on suit-

able surfaces and in an upright position. Sta-

tionary units must be permanently installed for

operation.

n

The units and components should not be oper-

ated in areas where there is a heightened risk

of damage. Observe the minimum clearances.

n

The units and components must be kept at an

adequate distance from flammable, explosive,

combustible, abrasive and dirty areas or

atmospheres.

n

Safety devices must not be altered or

bypassed.

1.8  Unauthorised modification

and changes

Modifications or changes to units and components

are not permitted and may cause malfunctions.

Safety devices may not be modified or bypassed.

Original replacement parts and accessories

authorised by the manufactured ensure safety. The

use of other parts may invalidate liability for

resulting consequences.

1.9  Intended use

The units are designed depending on the model

and equipment exclusively as a control unit for the

heat pump and the heating system.

Any different or additional use shall be classed as

non-intended use. The manufacturer/supplier

assumes no liability for damages arising from such

use. The user bears the sole risk in such cases.

Intended use also includes working in accordance

with the operating and installation instructions and

complying with the maintenance requirements.

Under no circumstances should the threshold

values specified in the technical data be exceeded.

1.10  Warranty

For warranty claims to be considered, it is essential

that the ordering party or its representative com-

plete and return the "certificate of warranty" to

REMKO GmbH & Co. KG at the time when the

units are purchased and commissioned.

The warranty conditions are detailed in the "Gen-

eral business and delivery conditions". Further-

more, only the parties to a contract can conclude

special agreements beyond these conditions. In

this case, contact your contractual partner in the

first instance.

 

 

 

 

 

5

Summary of Contents for Easy-Control EC1

Page 1: ...Operating and installation instructions Read the instructions prior to performing any task REMKO remote controls EC 1 Easy Control remote control for heat pumps 0242 2019 11 Edition 1 en_GB...

Page 2: ...rating instructions carefully before commis sioning using this device These instructions are an integral part of the system and must always be kept near or on the device Subject to modifications No li...

Page 3: ...notes for the operator 5 1 7 Safety notes for installation maintenance and inspection 5 1 8 Unauthorised modification and changes 5 1 9 Intended use 5 1 10 Warranty 5 1 11 Transport and packaging 6 1...

Page 4: ...fatal or cause serious injury WARNING This combination of symbol and signal word warns of a potentially hazardous situation which if not avoided may be fatal or cause serious injury CAUTION This combi...

Page 5: ...d or mounted on stable structures walls or floors n Mobile units must be set up securely on suit able surfaces and in an upright position Sta tionary units must be permanently installed for operation...

Page 6: ...tal protection and recycling Disposal of packaging All products are packed for transport in environ mentally friendly materials Make a valuable contri bution to reducing waste and sustaining raw mate...

Page 7: ...temperature C 5 45 Current consumption W 1 5 Timing error 1 Housing PC ABS fire resistant Suitable flush mounted socket mm 86 x 86 square or European 60 mm round box Wire clips mm2 Wire 2 x 1 5 or 1...

Page 8: ...sence program can also be set Using the room probe it is possible to realise room temperature guided regulation in the heating and cooling mode The installation is suitable for a standard flush mounte...

Page 9: ...tivation of the room temperature regulation If the display is switched off anti freeze protection mode is active 11 M key Switching from manual mode to present absent mode time program The following s...

Page 10: ...ng the time programs You have the option of storing six different time programs in the EC1 per day When doing so you can perform programming for days 1 5 Monday to Friday and day 6 Saturday as well as...

Page 11: ...temperature Room target temperature Press 10 x Switching time 3 time Minutes Press 11 x Switching time 3 time Hours Press 12 x Switching time 3 temperature Room target temperature Press 13 x Switchin...

Page 12: ...s 30 x Switching time 3 temperature Room target temperature Press 31 x Switching time 4 time Minutes Press 32 x Switching time 4 time Hours Press 33 x Switching time 4 temperature Room target temperat...

Page 13: ...Hours Press 48 x Switching time 3 temperature Room target temperature Press 49 x Switching time 4 time Minutes Press 50 x Switching time 4 time Hours Press 51 x Switching time 4 temperature Room targe...

Page 14: ...C 2 C 2 Switching hysteresis 1 C 5 C 1 C 3 Key lock 0 Key lock apart from on off 1 All keys locked 1 4 Probe type In Internal probe of the remote control Ex External probe AL Internal and external pr...

Page 15: ...G 2 4 A D N G 3 4 A D N G 4 4 A D N G 5 4 A D N G 6 4 A D N G S S n K L C O M I M 0T1 0T1 0T2 0T2 2 B 2 A 1 B V 2 1 D N G 1 A 1 4 S 0 4 S D N G V 5 0 2 S 3 4 S 2 4 S D N G V 5 1 2 S 5 4 S 4 4 S D N G...

Page 16: ...N G 0 4 A D N G 1 4 A D N G 2 4 A D N G 3 4 A D N G 4 4 A D N G 5 4 A D N G 6 4 A D N G S S n K L C O M I M 0T1 0T1 0T2 0T2 2 B 2 A 1 B V 2 1 D N G 1 A 1 4 S 0 4 S D N G V 5 0 2 S 3 4 S 2 4 S D N G V...

Page 17: ...as follows 1 For installation turn the round display clock wise to release the display from the mounting plate 2 Draw the ribbon cable out of the display to avoid damage 3 Connect the power supply to...

Page 18: ...s to the expert level on page 14 Under point c you can assign a BUS address for your room thermostats Make sure that all components to which you assign an address are assigned different addresses If a...

Page 19: ...the safety notes 4 General 4 Identification of notes 4 Notes for inspection 5 Notes for installation 5 Notes for maintenance 5 Personnel qualifications 4 Safety notes for the operator 5 Safety conscio...

Page 20: ...5232 606 260 E mail info remko de URL www remko de REMKO GmbH Co KG Klima und W rmetechnik Im Seelenkamp 12 32791 Lage Hotline within Germany 49 0 5232 606 0 Hotline International 49 0 5232 606 130 W...

Reviews: