Page 1: ...REMKO ATR 5 Electronic temperature regulation Operating equipment Edition EN I01...

Page 2: ......

Page 3: ...14 Circuit diagram 15 Customer data 16 17 Technical data 18 Carefully read this operating manual prior to commissioning using the units This operating manual is a translation of the German original T...

Page 4: ...of damage Safety notes Environmental protection and recycling Disposal of packaging All products are packed for transport in environmentally friendly materials You can make a valuable contribution to...

Page 5: ...by simultaneously pressing the and keys The selected operating mode is displayed on the right hand side of the display with the indicators 5 In hourly operation a second indicator is used to display t...

Page 6: ...be selected by simultaneously pressing on the two program keys and If the holiday program is activated in cooling mode an internal fixed set target temperature of 45 C is used for the control which n...

Page 7: ...in cooling mode NOTE Frost protection is always assured when the unit is active as the temperatures cannot be set lower than 5 C Reset key Two different resets are possible 1 Start up reset The Reset...

Page 8: ...he Set time menu was called The time program can be modified by briefly pressing the PROG key 16 program spaces are available These allow up to 112 switching times to be programmed Program point numbe...

Page 9: ...ure settings for daytime and nighttime are confirmed with the adjustment buttons 1 and 2 After pressing the PROG key with flashing program point number the unit returns to the operating mode from whic...

Page 10: ...a menu in which the different regulation parameters can be set The parameter is displayed in the left hand half of the display and the corresponding value or status in the right hand half of the disp...

Page 11: ...se two values can be set within 3 0 K limits under the SEnS menu item Example 20 7 C is shown on the unit display The temperature measuring instrument shows 19 9 C as the temperature at the sensor 0 8...

Page 12: ...ed to be changed Note This program point is not visible in Automatic mode Loc key lock Key lock prevents the daytime and nighttime temperatures from being modified with the rotary buttons After removi...

Page 13: ...5 m above the floor NOTE The external temperature probe must be installed such that it can record the average room temperature Draught and proximity to windows doors and heat sources etc must be avoi...

Page 14: ...s supply and relay connection lines cannot come into contact with low voltage lines such as probe lines minimum clearance 4 mm for lines with basic insulation The requirements of EN 60730 Part 1 must...

Page 15: ...r of the setback temperature Set daytime temperature 20 C Set nighttime temperature 15 C The daytime temperature will now be lowered to 18 C This results in the nighttime temperature of 13 C If the ni...

Page 16: ...evel P01 P02 P03 P04 P05 P06 P07 P08 P09 P10 P11 P12 P13 P14 P15 P16 The following tables have been compiled for entering the individual customer data Time program We reserve the right to modify the d...

Page 17: ...ference or Holiday temperature Proportional band Pulse duration Functions Sensor calibration Heating cooling 2 point pulse operation Keypad lock We reserve the right to modify the dimensions and desig...

Page 18: ...hours Display LCD display Operating voltage 230V 50Hz Power consumption approx 2 VA Relay contact 1 potential free changeover contact Max permissible switching current 10 4 A 230 V AC Electrical conne...

Page 19: ...19...

Page 20: ...5232 606 260 E mail info remko de URL www remko de REMKO GmbH Co KG Klima und W rmetechnik Im Seelenkamp 12 32791 Lage Hotline within Germany 49 0 5232 606 0 Hotline International 49 0 5232 606 130 W...