background image

NEVER LEAVE HEATER UNATTENDED WHILE BURNING 

OR WHILE CONNECTED TO A POWER SOURCE

© 2017, Pinnacle Climate Technologies, Inc. 

Kerosene Radiant Heater User’s Manual 

1

MASSACHUSETTS RESIDENTS: 

Massachusetts state law prohibits the use of this heater 

in any building which is used in whole or in part for human habitation. Use of this heating 

device in Massachusetts requires local fire department permit (M.G.L.C. 148, Section 10A).

NEW YORK CITY RESIDENTS: 

The New York City Fire Code prohibits the storage, 

handling and use of kerosene fueled heaters for space heating. Any person violating that 

provision may be punished by a fine up to $10,000 and a term of imprisonment of up to 6 

months.

 

Look for this icon throughout the manual for helpful tips on how to assemble, use 

and clean your OFR heater.

THE INSTALLATION OF THIS HEATER SHALL COMPLY WITH THE REGULATIONS OF 

THE AUTHORITIES HAVING JURISDICTION.

  

CALIFORNIA RESIDENTS: 

This product contains chemicals, 

including lead, known to the State of California to cause birth 

defects or other reproductive harm. 

Wash hands after handling.

DO NOT START THE HEATER WHEN EXCESS OIL HAS 

ACCUMULATED.

DO NOT START THE HEATER WHEN THE CHAMBER IS HOT.

 

WARNING

WARNING

WARNING

The products described in this manual are 

kerosene direct-fired, forced air heaters. Kerosene 

forced air heaters are primarily intended for use for 

temporary heating of buildings under construction, 

alteration or repair. Direct-fired means that all of 

the combustion products of the heater enter the 

heated space. This appliance is rated at 98% 

combustion efficiency, but does produce small 

amounts of carbon monoxide.

Carbon monoxide is toxic. Humans can tolerate 

only small amounts of carbon monoxide and so 

precautions should be taken to provide proper 

ventilation. Failure to provide proper ventilation 

in accordance with the instructions in this manual 

can result in death.

People with breathing problems should consult a 

physician before using this heater. 
Early signs of carbon monoxide poisoning 

resemble the flu. Symptoms of improper 

ventilation / carbon monoxide poisoning are:

Headache • Dizziness • Nausea 

• 

Dry Mouth 

Sore Throat 

 Burning of Nose and Eyes

If you experience any of these symptoms: 

GET FRESH AIR AT ONCE! 

Have your heater 

serviced and check for proper ventilation. Some 

people are more affected by carbon monoxide 

than others. These include: pregnant women, 

those with heart or lung problems, anemia or 

those under the influence of alcohol or at high 

altitudes. 

FOR OUTDOOR USE. INDOOR USE 

PERMITTED ONLY FOR: The temporary 

heating of adequately ventilated buildings or 

structures under construction, alteration or 

repair! Provide at least a three square foot  

(2,800 sq cm) opening of outside air for 

every 100,000 Btu / Hr heater rating. Refer to 

“Ventilation” on page 5 for further instructions.

RISK OF INDOOR 

AIR POLLUTION!

WARNING

CARBON 

MONOXIDE 

POISONING MAY 

LEAD TO DEATH!

DANGER

Summary of Contents for REM-125-OFR-O

Page 1: ...NGER Safety Information FIRE BURN INHALATION AND EXPLOSION HAZARD Keep combustibles such as building materials paper or cardboard a safe distance away from the heater as recommended by these instruc t...

Page 2: ...se for temporary heating of buildings under construction alteration or repair Direct fired means that all of the combustion products of the heater enter the heated space This appliance is rated at 98...

Page 3: ...heater with fuel in tank NEVER use with an external fuel tank Keep all combustible materials away from this heater Minimum Clearance From Combustibles 70 SS 125 OFR Top 4 ft 6 ft Sides 4 ft 6 ft Front...

Page 4: ...7 Pinnacle Climate Technologies Inc Kerosene Radiant Heater User s Manual 3 Features FUEL PRESSURE GAUGE BEHIND REMOVABLE COVER 70 SS 125 OFR Top Safety Guard Radiant Cone Front Safety Guard Radiant V...

Page 5: ...iver Figure 1 Figure 2 Attach the handle while still in the box for easier unpacking see Figure 2 Carry Handle 1 Black Screws 2 Step 1 Remove existing screws from shell ring on either side of heater s...

Page 6: ...attach wheels washers and nuts see Figure 6 2 Place main structure on wheel frame and fasten with long screws provided see Figure 7 3 Attach safety guard to front of heater with screws provided see F...

Page 7: ...direct sunlight or near a source of heat NEVER use Kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD Kerosene WILL NOT BURN PROPERLY IN THIS HEATER NOTE Ker...

Page 8: ...heater fails to ignite check this fuse first and replace if necessary Also check the power source to be sure the proper voltage is being provided to the heater 1 Complete steps 1 3 above 2 Push the p...

Page 9: ...ush with water use fresh Kerosene only SPARK PLUG Clean and re gap every 600 hours of operation or replace as needed After removing the Spark Plug clean the terminals with a wire brush Re gap the term...

Page 10: ...clean Kerosene or diesel to help loosen any particles see Figure 14a and 14b PHOTOCELL The photocell should be cleaned at least once per heating season or more depending on conditions Use a cotton sw...

Page 11: ...Spark Plug 3 Clean replace Fuel Filter 4 Clean replace Nozzle 5 Rinse out fuel tank with clean fresh Kerosene diesel 6 Inspect all electrical connections See Wiring Diagrams Page 11 7 Re attach Transf...

Page 12: ...ER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 2017 Pinnacle Climate Technologies Inc Kerosene Radiant Heater User s Manual 125 OFR 11 Wiring Diagram AC 120V 60Hz AC 250V 3 15A ELECT...

Page 13: ...HILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 2017 Pinnacle Climate Technologies Inc Kerosene Radiant Heater User s Manual Exploded View 12 25 23 24 9 21 22 20 19 26 10 7 28 6 4 3 1 2 27 8 12 13 2...

Page 14: ...75 027 0650 9 Ignitor 75 025 0120 10 Main PCB Assembly 75 025 0400 11 Tip Over Sensor 75 051 0200 12 Cooling Motor Assembly 75 047 0250 13 Cooling Fan 75 047 0200 14 Handle 75 001 0060 15 Temperature...

Page 15: ...NING OR WHILE CONNECTED TO A POWER SOURCE 2017 Pinnacle Climate Technologies Inc Kerosene Radiant Heater User s Manual 1 2 4 3 5 6 7 8 9 10 11 12 13 14 15 16 17 18 24 20 22 21 30 23 26 19 34 27 29 42...

Page 16: ...72 027 0100 11 Main PCB and Fuse 72 025 0450 12 Tip Over Sensor 75 051 0200 13 Power Cord 72 032 0150 14 Power Switch 72 012 0120 15 Back Cover 72 013 0110 16 Panel sub PCB 72 014 0100 17 Blower Moto...

Page 17: ...If Pinnacle Climate Technnologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other expres...

Page 18: ...1 Industrial Blvd 101 Sauk Rapids MN 56379 USA Toll Free 866 676 1989 Fax 320 251 2922 Web www remingtonheater com Email info pinnacleclimate com 2017 Pinnacle Climate Technologies Inc...

Page 19: ...MADURAS INHALACI N Y EXPLOSI N Mantenga los combustibles como materiales de construcci n papel o cart n a una distancia prudente del calentador seg n lo recomiendan estas instrucciones Nunca use el ca...

Page 20: ...e para calefacci n temporal de edificios en construcci n modificaci n o reparaci n Fuego directo significa que todos los productos de combusti n del calentador ingresan en el espacio calentado Este ap...

Page 21: ...ble en el tanque NUNCA lo use con un tanque de combustible externo Mantenga todos los materiales combustibles lejos de este calentador Separaci n m nima entre el calentador y materiales combustibles 7...

Page 22: ...CARCAZA CARCAZA ASA CAJA DE CONTROL LUZ INTERRUPTOR DE FUNCIONAMIENTO CABLE EL CTRICO INDICADOR DE COMBUSTIBLE TAPA DE COMBUSTIBLE TANQUE DE COMBUSTIBLE CAJA DE ENFRIAMIENTO MAN METRO DE COMBUSTIBLE...

Page 23: ...igura 2 Coloque el asa cuando a n est en la caja para facilitar el desempaque vea la Figura 2 Manija 1 Tornillos negros 2 Paso 1 Retire los tornillos existentes del anillo de la carcasa en ambos lados...

Page 24: ...a 6 2 Coloque la estructura principal en el marco de las ruedas y aj stela con los tornillos largos suministrados vea la Figura 7 3 Instale la protecci n de seguridad en la parte delantera del calenta...

Page 25: ...seno que se haya estado almacenado de una temporada a la siguiente El queroseno se deteriora con el tiempo EL QUEROSENO VIEJO NO SE QUEMAR ADECUADAMENTE EN ESTE CALENTADOR NOTA El queroseno debe almac...

Page 26: ...mero este fusible y reempl celo si es necesario Tambi n revise la fuente de alimentaci n el ctrica para asegurarse que se est suministrando el voltaje correcto al calentador 1 Complete los pasos 1 a 3...

Page 27: ...y reajuste la separaci n entre los electrodos de la buj a despu s de cada 600 horas de funcionamiento o reempl cela seg n sea necesario Despu s de extraer la buj a limpie las terminales con una cepil...

Page 28: ...iarse al menos una vez por cada temporada de calefacci n o m s seg n las condiciones en que est Utilice un hisopo de algod n remojado en agua o alcohol para limpiar la lente de la fotoc lula Aseg rese...

Page 29: ...r del tanque con queroseno o di sel nuevo y limpio 6 Inspeccione todas las conexiones el ctricas Consulte los Diagramas el ctricos en la p gina 11 7 Reconecte los cables del transformador a la buj a 8...

Page 30: ...A BUJ A ENCENDEDOR MOTOR DE ENFRIAMIENTO PLACA DE CIRCUITOS IMPRESOS LUZ DE FUNCIONAMIENTO LUZ DE REVISI N DE ERROR PCI DE CONTROL INTERRUPTOR ANTIVUELCO INTERRUPTOR DE LIMITE DE TEMPERATURA FOTOC LUL...

Page 31: ...DO O MIENTRAS EST CONECTADO A UNA FUENTE DE ALIMENTACI N 2017 Pinnacle Climate Technologies Inc Manual del usuario del calentador radiante de queroseno Vista detallada 12 25 23 24 9 21 22 20 19 26 10...

Page 32: ...le 75 027 0650 9 Encendedor 75 025 0120 10 Conjunto de la placa de circuitos impresos principal 75 025 0400 11 Interruptor antivuelco 75 051 0200 12 Conjunto del motor de enfriamiento 75 047 0250 13 V...

Page 33: ...TRAS EST CONECTADO A UNA FUENTE DE ALIMENTACI N 2017 Pinnacle Climate Technologies Inc Manual del usuario del calentador radiante de queroseno 1 2 4 3 5 6 7 8 9 10 11 12 13 14 15 16 17 18 24 20 22 21...

Page 34: ...2 027 0100 11 Placa de circuitos impresos principal y fusible 72 025 0450 12 Interruptor antivuelco 75 051 0200 13 Cable el ctrico 72 032 0150 14 Interruptor de encendido 72 012 0120 15 Cubierta poste...

Page 35: ...limate Technologies Inc descubre que el art culo est en condiciones normales de funcionamiento o que no est defectuoso se devolver el art culo con el flete por cobrar Esta Garant a Limitada reemplaza...

Page 36: ...dustrial Blvd 101 Sauk Rapids MN 56379 EE UU Llamada sin costo 866 676 1989 Fax 320 251 2922 Web www remingtonheater com Correo electr nico info pinnacleclimate com 2017 Pinnacle Climate Technologies...

Reviews: