RemVu 2

www.remguard.com

Setting the standard for remotely monitored CCTV.

7735

7782

I

nstallation Guide

Summary of Contents for RemVu 2

Page 1: ...RemVu 2 www remguard com Setting the standard for remotely monitored CCTV 7735 7782 Installation Guide...

Page 2: ...RemGuard 2011 2 RemVu2 Contents Introduction 3 Features 4 Introduction 7 Installation 8 Installation Details 17 Troubleshooting 20 Specification 21 Index 23...

Page 3: ...opened automatically or staff can enter a site via a specific route at key times without comprising the security of the overall site The RemVu2 provides advanced CCTV features within a highly scalabl...

Page 4: ...s Web based configuration allows system adjustments without the need for site visits BS8418 Compliant Programmable entry exit routes and times part set zones Remote alarm transmission Can transmit ove...

Page 5: ...g Strike The unit has some in built protection for lightning strike however it is recommended that isolation transformers be fitted to the system in areas where lightning is a common occurrence Regula...

Page 6: ...n Ensure the RemVu2 is properly ventilated to protect from overheating Ensure there is a 3cm gap on both sides of the unit Ensure the unit is not located anywhere it could be subject to mechanical sho...

Page 7: ...gh the gland in the housing An optional 12V battery can be connected to the flying leads using the 1 4 spade sockets The 1TB hard drive is connected via SATA to the VSRV board Power is drawn from the...

Page 8: ...USB NET1 AUDIO AUDIO OUT OUT VID 1 MON B VID 2 VID 3 A VID 13 VID 8 VID 6 VID 4 VID 5 VID 7 VID 9 VID 10 VID 12 VID 11 VID 14 VID 15 VID 16 The unit supports a main monitor via Mon A and a spot monito...

Page 9: ...sing to a fused spur connection To be compliant with wiring regulations in some countries an Alarm Security device should be connected to a fused spur and not a wall outlet socket check local regulati...

Page 10: ...CAT5 cable to connect the Ethernet RJ 45 10 100Mbps connection marked NET1 to the network The unit is normally configured with a static IP address 192 168 0 250 Step 5 Connecting Audio USB NET1 AUDIO...

Page 11: ...All alarm connections are made to the internal board To access this remove the 5 five securing screws on the cover of the RemVu2 enclosure Step 6 Alarms Relays Alarms The unit supports thirty normall...

Page 12: ...e the 5K6 ohm resistor Open Circuit Tamper the resistive value is infinity as the circuit has been cut and therefore is open Short Circuit Tamper the resistive value is 0 Ohms Alarm units wired withou...

Page 13: ...held on it may be worth checking the load presented to the relay with an ammeter If the load has been excessive the relay may be permanently damaged and stuck in the closed contact position In this c...

Page 14: ...nd PPP serial port 3 4 offers RS 485 connectivity Key Port 1 Serial Port 1 2 Serial Port 2 3 Serial Port 3 4 Serial Port 4 Serial ports have two main uses 1 Connecting twisted pair telemetry for PTZ c...

Page 15: ...stu outputs that can be wired into the Redcare or Dualcom system These are located on the board as P6 and P7 STU outputs can be configured to drive numerous indications commonly line connection failur...

Page 16: ...RemGuard 2011 16 RemVu212V Supply A 12V supply is available from Terminal P19 12V is on the second pin indicated...

Page 17: ...RemGuard 2011 17 RemVu2 Installation Details Alarms Input legend Detector device number type Comment 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 System Set Unset...

Page 18: ...RemGuard 2011 18 RemVu2 Relays Input legend Detector device number type Comment 1 Set Unset Indicator 2 3 4 5 6 7 8 Watchdog 9 10...

Page 19: ...d connections Comment GND Gnd STU PWR Not to be used Input 1 Input 2 GND Gnd GND Gnd GND Gnd GND Gnd 01 Fire alarm 02 Personal attack 03 Intruder alarm 04 Set unset indication 05 Paknet failure 06 ISD...

Page 20: ...nnector If the cable run is quite long hum may be induced anyway Try turning the bass control on the amplifier to the minimum setting it should not affect audio quality Hissing noise from speakers A c...

Page 21: ...software control Any of these inputs can be configured to be a Set Unset input using a keypad keyswitch or radio fob etc Individual alarm responses include move camera to preset activate relay remote...

Page 22: ...files QCIF CIF 2CIF and 4CIF resolution DATA PORTS Serial Ports 2x RS485 RS422 2x RS232 Ethernet 1x Ethernet RJ 45 10 100 connection Keyboard 1x RJ12 Compatible with Dedicated Micros KBC2 keyboard WE...

Page 23: ...Lightning Strike 5 Loud hum from loudspeaker system 20 MONITOR VIEWING 21 Power Sources 5 POWER SUPPLY 22 Read Instructions 5 Rear Panel connections 7 RECORD RATES 21 Regulatory Notes and FCC and DOC...

Page 24: ...m Setting the standard for remotely monitored CCTV RemGuard Visual Management 1200 Daresbury Park Daresbury Warrington UK WA4 4HS 0870 573 6482 remenquiry remguard co uk MI I RVU2 E1 2 Copyright AD Gr...