![Remer SE 33 User Manual Download Page 1](http://html1.mh-extra.com/html/remer/se-33/se-33_user-manual_1437019001.webp)
1
SE 33
Automatic Inductive Urinal Flusher User Manual
Touch less battery-operates Urinal Flusher
Use (Urinal cycle steps)
1. The photoelectric cell is covered by the user;
2. After 2 seconds the there is the first cleaning flush for 2 seconds;
3. Photoelectric cell covering time depends on how long the user stands in front of it;
4. Photoelectric cell gets uncovered;
5. After 3 seconds there is the final flush, longer then the first
Simple manufacture, it includes one stop valve, one filter and one flushing pipe.
Primary Application
Public places.
Technical Data
Working pressure: 0.1 – 0.4 Mpa
Power supply: DC6V (four 1.5V “AAA” size alkaline batteries)
Inlet calibre: G1/2’’
Recognition range: 35 cm
Installation mode: Exposed
Checking List
N° Parts Quantity
Remarks
1 Main
body
1
2 Flushing
pipe
1
3 Decorative
cover
2
4 Flushing
controller
2
5
Alkaline battery
4
1.5V “AAA”
6 Special
spanner
1
7 User
manual
1
8 Sealed
ring
1
Notes
1. Check carefully packed parts before installation and contact us for any
further request.
2. All parts are packed in suitable bags, please do not bump them excessively.
Names of the parts