Component
Description
SCB-02
Information about the PCB controlling the zones for heating and domestic hot water
CB-09
Information on the input/output control PCB
9.9
Menu tree
Level 1 menus accessible with the button:
Level 1 menu
Installation Setup
Commissioning Menu
Advanced Service Menu
Error History
System Settings
Version Information
9.10 List of parameters
9.10.1 Introduction to parameter codes
The controls platform makes use of an advanced system to categorise
parameters, measurements and counters. Knowing the logic behind these
codes, makes it easier to identify them. The code consists of two letters
and three numbers.
The first letter is the category the code relates to.
A
Appliance: Appliance
C
Circuit: Zone
D
Domestic hot water: Domestic hot water
G
Gas fired: Gas-fired heat engine
P
Producer: Central heating
Category D codes are appliance controlled only. When the domestic hot
water is controlled by an SCB, it is handled like a circuit, with C-category
codes.
The second letter is the type.
P
Parameter: Parameters
C
Counter: Counters
M
Measurement: Signals
The number is always three digits. In certain cases, the last of the three
digits relates to a zone.
9.10.2 Changing the parameters
The boiler’s control unit is set for the most common central heating
systems. These settings will ensure that virtually every central heating
system operates effectively. The user or the installer can optimise the
parameters as required.
On
Fig.58
Code on a OEtroCom-3
AD-3001373-02
00:12
......
......
........ .......
........ .......
....................
..... ... ....... .... .. ..... ....... .... ..... .......
..... ... ....... .... .. ..... ....
.........
..... ... ....... ....
..... ... ....... ....
....... .... .. ..... ....
.......
....... ...........
......
.....
...
CP010
CP010
Fig.59
First letter
AD-3001375-01
C
P010
Fig.60
Second letter
AD-3001376-01
C
P
010
Fig.61
Number
AD-3001377-01
CP
010
9 Settings
48
MID _HMI T-control - Gas 120 ACE
7717201 - v03 - 25062019