background image

Warning

Caution with main supply and live wires. Install with qualified technician or trained 
personnel.

Installation Guide   

(PLT-412)

C

Ceiling Suspension

Ceiling Mount

Important Note

Do not adjust the Upper Limit of the lift higher than the original factory
preset position.

If adjusted, the lift will move into the frame and be stopped by force
and not the Upper Limit Switch. This will cause overheating of the
motor, rendering the lift to being unable to operate properly.

-

+

-

+

Adjust  “

 

-

 ”  : Less lift retraction

Adjust  “ 

+

 ”  : More lift retraction

Adjust “ 

-

 

“  : Less lift drop

Adjust “ 

+

 “  : More lift drop

Front
View

Upper Limit

Lower Limit

Allen Key

51.00 cm

1 0

m

5 .

0 c

 

8.00 cm

4.50 cm

A) Drill Dia. 10mm holes to a depth of 35mm.
    (Note: Do not drill too deep)

B) Insert M8 anchor into the hole.
C) Use pin punch to expand the anchor.

Adjustable
7 cm to
138 cm

Hammer

Pin Punch

M8 Anchor

10mm Drill

Power Drill

35

Website: www.remacotech.com

COPYRIGHTS 1998

REMACO TECHNOLOGIES PTE LTD

Wall

Swtich

D) Connection of all cables to the
     MPC-850 (Refer to Installation
     Guide for MPC-850)

Types of Installation Mount

Steps for Installation

Step 1

Step 2

Step 3

Step 4

PLT

V: 1.0

PLT-412

All connections
are to the MPC

Connect

to the MPC

MPC

For connection details,

please refer to the

Installation Guide

provided

Important Note

MPC

Sensor

UP

DO WN

Screen Infrared Remote 

(4-Channel Control)

STOP

UP

DO WN

STOP

UP

DO WN

STOP

UP

DO WN

STOP

Ch1

Ch2

Ch3

Ch4

4-Channel

IR Remote

Projector

Projector Lift

Continue next page

Front

Back

Front

Back

12 x 4 Nos.

54.50 cm

55.00 cm

5. 0

 cm

4 5

18.50 cm

Adjustable
20-32cm

Red Knob

M8 Threaded
(Optional)

8.00 cm