LIGHTING THE PILOT

The manifold units are equipped with standing pilots and each should be lit immediately after the gas 
is supplied to the equipment.

1.  Before attempting to light the pilots, turn off the main gas valve to the equipment and wait 5 minutes to clear 

the gas.

2.  Turn off all gas control knobs.
3.  Turn on control valve and light all pilots.
4.  The pilot burner must be lit from the top. Hold an ignition source and light the pilot. When the flame is 

stable, remove ignition source.

5.  Turn off the main gas valve to shut down the equipment.
There is one pilot for each burner. The hotplate is equipped with standing, unmonitored pilots. Gas will flow from 
the pilots as soon as the main gas supply to the unit is turned on. Standing pilots should be adjusted to provide 
a slight yellow tip on the flame. Air shutters on the main burners must be individually adjusted to provide a blue 
flame. All traces of yellow should be adjusted out of the burner flame. 
The hotplate is a free vented appliance. All products of combustion and the heat generated by the burners 
pass through the grates. When meat is placed on the grates, this blocks the venting and causes a temperature 
build-up.

PILOT FLAME HEIGHT ADJUSTMENT:

•  The pilot flame on the equipment has been factory adjusted. When adjustment is necessary, adjust the pilot 

flames as small as possible but high enough to light the burner immediately when the burner valve is turned to 
the highest setting. Access to the pilot flame adjustment screw is obtained through the holes in the front panel

BURNER ADJUSTMENT:

•  Remove the front panel to gain access. Turn burner valve knob to highest setting. Slowly decrease the air 

shutters to give a soft blue flame having luminous tips. Then slowly increase opening to a point where the 
yellow tips disappear and a hard blue flame is obtained.