background image

Reliable Automatic Sprinkler Co., Inc.,

 103 Fairview Park Drive, Elmsford, New York 10523

Model F3QR56 Dry
K5.6 (80 metric)
Quick-Response,
Standard Spray Sprinklers

Bulle

tin 157 Sep

tember 2021

Bulletin 157 September 2021

Features

1. 

Available in the following configurations:

•  Pendent with standard escutcheon
•  Pendent with Model HB extended escutcheon
•  Pendent with Model FP recessed escutcheon
•  Pendent with Model F1 recessed escutcheon
•  Concealed Pendent with Model CCP cover plate
•  Horizontal Sidewall with Standard escutcheon
•  Horizontal Sidewall with Model HB extended escutch-

eon

•  Horizontal Sidewall with Model FP recessed escutch-

eon (FM Standard Response)

•  Horizontal Sidewall with Model F1 recessed escutch-

eon (FM Standard Response) 

•  Upright

2.  Available with 1” NPT, ISO7-1R1, 3/4” NPT, or ISO7-

1R3/4 inlet fitting.

3. 

3/4” NPT inlet fittings permit replacement of older 3/4” 

inlet dry sprinklers without changing to a larger sprinkler 

fitting.

4.  Sprinklers, escutcheons, and cover plates are available 

in a wide variety of standard and special application fin

-

ishes.

5.  White polyester, black polyester, and Electroless Nickel 

PTFE (ENT) finish sprinklers are cULus Listed as Corro

-

sion Resistant. 

6. 

Available with cULus Listed 250 psi (17.2 bar) pressure 
rating for Dry Pendent and select HSW configurations. 

FM Approved for 175 psi (12 bar).

Product Description

Model F3QR56 Dry sprinklers are quick-response, standard 

coverage sprinklers with a nominal K-Factor of 5.6 (80 metric). 
Available in Dry Pendent, Dry Horizontal Sidewall, and Dry Up-

right configurations, Model F3QR56 Dry sprinklers all use a 3 

mm glass bulb operating element. See the Temperature Rat-
ings table in this Bulletin for available temperature ratings. Mod-
el F3QR56 Dry sprinklers are intended for installation on wet-
pipe, dry-pipe, or preaction sprinkler systems in accordance 

with NFPA 13, FM Property Loss Prevention Data Sheets, and 

other applicable installation standards.

Model F3QR56 Dry Pendent and Sidewall sprinklers are avail-

able with a variety of escutcheon options as illustrated in Figs. 
1 through 3 and Figs. 5 through 9. In addition, Model F3QR56 
Dry Pendent sprinklers are also available with the Model CCP 
conical concealed cover plate as illustrated in Fig. 4. Available 

sprinkler, escutcheon, and cover plate finishes are identified in 

the Finishes table in this Bulletin. The Model F1 escutcheon, 
Model FP escutcheon, and Model CCP cover plate are the only 
recessed escutcheons and cover plate listed for use with Model 
F3QR56 Dry sprinklers; the use of any other recessed escutch-
eon or cover plate with Model F3QR56 Dry sprinklers will void 
all guarantees, warranties, listings and approvals.

Concealed

(See Fig. 4)

Recessed FP Pendent

(See Fig. 3)

 Recessed F1

Horizontal Sidewall

(See Fig. 9)

 Horizontal Sidewall

(See Fig. 6)

Pendent

(See Fig. 1)

Recessed F1 Pendent

(See Fig. 5)

 Recessed FP 

Horizontal Sidewall

(See Fig. 8)

Pendent / HB

(See Fig. 2)

Horizontal Sidewall / HB

(See Fig. 7)

Upright

(See Fig. 10)

Summary of Contents for F3QR56

Page 1: ...re quick response standard coverage sprinklers with a nominal K Factor of 5 6 80 metric Available in Dry Pendent Dry Horizontal Sidewall and Dry Up right configurations Model F3QR56 Dry sprinklers all...

Page 2: ...2 to 48 50 to 1200 mm cULus FM NYC 1 NPT or ISO7 1R1 HB Extended Escutcheon 3 1 2 to 48 90 to 1200 mm F1 Recessed Escutcheon FP Recessed Escutcheon CCP Cover Plate F3QR56 Dry Horizontal Sidewall Stan...

Page 3: ...rinkler Temperature Rating Cover Plate Temperature Rating Maximum Ceiling Temperature Listings and Approvals 1 Ordinary Orange 135 F 57 C 135 F 57 C 100 F 38 C cULus FM NYC Red 155 F 68 C Intermediate...

Page 4: ...ments for 3 4 connections Sprinkler Guard Model C2 Finish Combinations Standard Escutcheon Sprinkler Escutcheon 2 3 Bronze Polished Stainless Bronze Laquered Brass Chrome Polished Stainless White Poly...

Page 5: ...12 7mm to 12 7mm A dimension adjustment range Fig 2 5 Sprinkler Guard Model C2 Finish Combinations HB Escutcheon Sprinkler Escutcheon 2 3 Bronze Chrome Chrome Chrome White Polyester 1 White Polyester...

Page 6: ...or 3 4 connections Finish Combinations FP Recessed Escutcheon Sprinkler 1 Escutcheon 3 4 Bronze Chrome Bronze Brass Chrome Chrome White Polyester 2 White Polyester Black Polyester 2 Black Polyester Cu...

Page 7: ...the Model F3QR56 Dry Pendent sprinkler with the Model CCP cover plate in ceilings which have positive pressure in the space above Fig 4 7 Finish Combinations CCP Conical Cover Plate Sprinkler Cover P...

Page 8: ...g 5 8 Finish Combinations F1 Recessed Escutcheon Sprinkler Escutcheon 2 3 Bronze Chrome Bronze Brass Chrome Chrome White Polyester 1 White Polyester Black Polyester 1 Black Polyester Custom Color Poly...

Page 9: ...m in 1 4 6mm increments for 3 4 connections Finish Combinations Standard Escutcheon Sprinkler Escutcheon 2 3 Bronze Polished Stainless Bronze Laquered Brass Chrome Polished Stainless White Polyester 1...

Page 10: ...djustment provides 12 7mm to 12 7mm A dimension adjustment range Fig 7 Finish Combinations HB Escutcheon Sprinkler Escutcheon 2 3 Bronze Chrome Chrome Chrome White Polyester 1 White Polyester Black Po...

Page 11: ...ith respect to the protected space Fig 8 Finish Combinations FP Recessed Escutcheon Sprinkler 1 Escutcheon 3 4 Bronze Chrome Bronze Brass Chrome Chrome White Polyester 2 White Polyester Black Polyeste...

Page 12: ...ctions Fig 9 Finish Combinations F1 Recessed Escutcheon Sprinkler Escutcheon 2 3 Bronze Chrome Bronze Brass Chrome Chrome White Polyester 1 White Polyester Black Polyester 1 Black Polyester Custom Col...

Page 13: ...127 mm to 1219 mm Fig 10 Finish Combinations Upright Sprinkler Escutcheon Bronze NA Electroless Nickel PTFE 1 NA Notes 1 UL Listed as Corrosion Resistant 2 Escutcheons do not carry corrosion resistan...

Page 14: ...Fig 11 14...

Page 15: ...Fig 12 15...

Page 16: ...Fig 14 Model XLO2 Wrench Fig 13 Model F3R Wrench 16...

Page 17: ...Fig 15 17...

Page 18: ...O2 wrench is designed to fit into the cup and engage the wrench boss as shown in Fig 14 Do NOT wrench any part of the sprinkler assembly other than the wrench boss When inserting or removing the wrenc...

Page 19: ...rd Escutcheon 2 1 8 54 mm F3R Not Applicable HB Extended Escutcheon 2 1 2 64 mm F3R F1 Recessed Escutcheon 2 1 4 57 mm XLO2 FP Recessed Escutcheon 2 1 2 64 mm XLO2 CCP Cover Plate XLO2 F3QR56 Dry Hori...