Condensate Purifier Assembly Maintenance
Maintaining and replacing the oil absorption media in the Condensate Purifier Assembly (CPA) can be done
while the ThermoJet is operating.
Replace oil absorption media sock if saturated. This absorption media sock should remain effective for two to
four weeks. Periodic visual inspection is the only way to determine if sock is saturated.
To replace the absorption media sock locate the cover cap on the CPA housing. Remove the cap and pull the
media out of the housing.
Inspect the interior of the housing and clean as necessary. Install a new absorption media sock and re-install
the cover cap.
Locate the CPA cover
cap. Remove cap to
access the absorbent
media sock