VACURET 

Summary of Contents for VACURET DIGIT

Page 1: ...g Instructions LABORATORY EQUIPMENT IN STAINLESS STEEL VACURET DIGIT REITEL Feinwerktechnik GmbH Senfdamm 20 49152 Bad Essen Phone 49 0 5472 9432 0 Fax 49 0 5472 9432 40 www reitel com info reitel com...

Page 2: ...top stand Any other use or beyond shall be deemed not to be intended The user or operator of the device is liable for the resulting damages Prior to installation of the device operating instructions a...

Page 3: ...NS 7 INSTALLATION 8 INSTALLATION 8 KEY SYMBOLS 8 OPERATION 9 OPERATION SEQUENCE FOR PRE REGISTERED PROGRAMS 9 SETTING SAVING MIXING PARAMETERS EDITING EXISTING PROGRAMS 10 MANUAL MODE 11 MIXING BOWL F...

Page 4: ...00 ml Order No 21304000 Mixing bowl 600 ml Order No 21213000 Mixing bowl 1000 ml Order No 21306000 Mixing bowl for alginates 150 ml Order No 21307000 Mixing bowl for alginates 400 ml Operating Element...

Page 5: ...n 600 W Height width depth 290 155 285 mm Height with depth incl stand 710 220 360 mm Weight 8 kg 15 kg incl stand Speed variable 200 600 t min Vacuum max 98 Memory locations 28 Sound level 70 dB A Ho...

Page 6: ...he manufacturer s warranty expires The device should be set up in a clean well ventilated room if necessary under a hood Supporting surfaces should be straight flat and adequately stable Don t place a...

Page 7: ...than intended or material containing solvents which are dangerous to health The pump and other conducting components are not explosion proof The use of flammable substances is therefore prohibited Do...

Page 8: ...a socket The device is now ready for use If the device is not used for a long period of time disconnect it from the mains Key symbols 10 Program selection according to material to be mixed 11 Add pro...

Page 9: ...o select the required program 10 and push the rotary control knob 2 to open the program 3 If you want to change settings use the edit icon 20 to adjust them see chapter 4 2 Push the filled bowl 9 into...

Page 10: ...mixing Note You can also delete a program 4 Use the letter keys to save the program under a name at your choice and confirm letter after letter by pressing the rotary control knob 2 Use the right arr...

Page 11: ...e rotary control knob 2 is used to increase or decreas values Push the control knob to confirm your settings Use the Storing key 23 in the right lower part of the display to save your settings 2 Turn...

Page 12: ...s on the material used see manufacturers instructions During the first 10 seconds a reduced mixing time of approx 400 min 1 should be selected then speed should be increased to 600 min 1 5 Push the fi...

Page 13: ...ually check each function Cracks in the bowl Note Do not use spirit or other solvents for cleaning or mixing in the bowl Referring to chapter 2 2 the bowl 9 is not resistant against some chemicals Pro...

Page 14: ...REITEL Feinwerktechnik GmbH offer a 1 year s warranty beginning from the proven date of purchase This warranty covers all defects traceable to materials design or workmanship The following warranty re...

Page 15: ...e end of the original 1 year warranty 5 If the unit is destined to be operated in another country than originally intended and manufactured for modifications to the product might be necessary to compl...

Page 16: ...the product is continued to be operated despite a functional defect 7 The warranty is device specific and may be claimed within the warranty period by any person who has legally acquired the device 8...

Page 17: ...o as to give effect to the intent manifested by the provision by the provision held invalid illegal or unenforceable and to give effect to section 13 hereof 14 Should you need to borrow a device while...

Page 18: ...l Regulations According to valid laws our devices are correctly disposed of according to B2B Regulations for proper disposal of commercial end products Please contact your local dealer for detailed in...

Page 19: ...Stck piece E6555630 Dichtring f r 600ml Becher Sealing ring for 600 ml bowl 1 Stck piece E7011700 Dichtring f r Becheraufnahme mit Kleber E7056200 Sealing ring for bowl support with glue E7056200 1 St...

Page 20: ...20 Wall mounting Drilling template Please refer to indicated dimensions Drilling template not to scale 1 1...

Page 21: ...21 EU Directive...

Page 22: ...pliance with Quality Management ISO 13485 2016 incorporating established standards REITEL Feinwerktechnik GmbH Senfdamm 20 49152 Bad Essen Phone 49 0 5472 9432 0 Fax 49 0 5472 9432 40 www reitel com i...