Reison 10-387 Manual Download Page 1

  


 

 

 

Armboard 10-387 including versions  

 

 

 

 

 

Version 

Description 

10-387 

Rotation clamp (EU 25x10 mm rail) 

10-387-UK 

Rotation clamp 

(UK 1¼ ” x ¼ ” 

rail) 

10-387-US 

Rotation clamp 

(US 1⅛ ’’ x ⅜ ’’ 

rail) 

10-387-AUSTRALIA 

Rotation clamp (AUS 1 ½ 

’’ x 

¼ 

’’ 

rail) 

10-387-F 

Rotation clamp (EU 25x10 mm rail), incl. moulded pad 

10-387-F-UK 

Rotation clamp 

(UK 1¼ ” x ¼ ” 

rail), incl. moulded pad 

10-387-F-US 

Rotation clamp 

(US 1⅛ ’’ x  ⅜ ’’ 

rail), incl. moulded pad 

10-387-H 

Rotation clamp (EU 25x10 mm rail), incl. Medisoft pad 

10-387-UK-H 

Rotation clamp 

(UK 1¼ ” x ¼ ” 

rail), incl. Medisoft pad 

 

 

 

Warning! This symbol indicates important information related to safety. Follow these 
instructions carefully.

 

 

 

 

Read User Manual before use! It is important to fully understand the content of the user 
manual before attempting to use the equipment. 

 

 

 

2020-10-30 
Document number: M10-387EN rev.01 

  Armboard 10-387

 

EN

G

LIS

H

 

Summary of Contents for 10-387

Page 1: ...1 x rail incl moulded pad 10 387 F US Rotation clamp US 1 x rail incl moulded pad 10 387 H Rotation clamp EU 25x10 mm rail incl Medisoft pad 10 387 UK H Rotation clamp UK 1 x rail incl Medisoft pad Warning This symbol indicates important information related to safety Follow these instructions carefully Read User Manual before use It is important to fully understand the content of the user manual b...

Page 2: ...en loosening the lock lever to adjust the height support underneath the armboard to prevent it from uncontrolled descend into the bottom position Remove the armboard or secure it over the operating table during transport For use during diathermy procedures the cushion must be fixed to the plate by using e g Velcro straps to prevent from sliding The complete device needs to be covered with e g ster...

Page 3: ...3 User instruction Installation Position adjustment 1 2 90o A B A A B B ...

Page 4: ...be performed by authorized personnel only Altering the construction without a written consent from the manufacturer is strictly forbidden Adjusting the lock mechanism Tool 3 mm hex key To turn 1 8 of a round is enough for adjustment Complete lock should be achieved when the lever is at rest Too strong lock may lead to damage in case of e g collision Adjusting the lever position Tool 3 mm hex key W...

Page 5: ... to clean the ball joint Wipe it dry The ball joint device shall be oiled with hydraulic oil ISO VG32 or similar Control Check that there are no loose parts and that there is no damage to any part The lock function is checked by locking and unlocking the top in different positions If a cushion is used check that it is clean and is not damaged Annual service Once a year the arm board shall be caref...

Page 6: ...S 10547 UK 10543 6 Gear plate 1 10486 10486 10486 7 Guide 1 10320 10320 10320 8 Gear ring 1 10316 10316 10316 9 Screw MKFXS M4x10 A2 1 10 Lock handle 1 10346 10346 10346 11 Stud 1 10429 10429 10429 12 Set screw MT6SS M5x6 A2 2 13 Screw MC6S M6x30 FZ 2 14 Shaft 1 10009 10009 10009 15 Spring 1 10013 10013 10013 16 Preassure pin 1 10012 10012 10012 17 Plunge 1 10711 10711 10711 18 Eccentric 1 11165 1...

Page 7: ...ion corresponding to a patient weight of 200 kg according to EN 60601 1 and EN 60601 2 Weight 4 3 kg Material armboard Stainless steel Version UDI DI Dimension H x W x L 10 387 07350111830595 229 x 180 x 670 mm 10 387 UK 07350111830663 229 x 180 x 670 mm 10 387 US 07350111830687 229 x 180 x 670 mm 10 387 AUSTRALIA 07350111830601 229 x 180 x 670 mm 10 387 F 07350111830618 229 x 180 x 670 mm 10 387 ...

Page 8: ...8 Reison Medical AB Eriksbergsvägen 32A 734 92 Hallstahammar SWEDEN 46 0 220 433 99 I order reison se I info reison se ...