8.2 Controlling the Microprocessor
8.2.1 Input parameters of the MWS9-5-microprocessor
Reset ( Versions same or newer than 2.28):
'!' '*' <#13>
Changing the BAUD-Rate:
'!' 'B' <X> <#13> ; 0 < X < 8 :
BAUD-Rate for X = 0 : 300
1 : 600
2 : 1200
3 : 2400
4 : 4800
5 : 9600 (Default)
6 : 19200
7 : 38400
8 : 76800
NOTE:
After voltage is applied, the sensor ALWAYS is set to 9600 BAUD. If the Baud-rate has been changed
by mistake, you can set the sensor to its correct baud-rate during the RAM-test (.........) .
Continue the output after an interruption
'!' 'C' <#13>
Input-flags for control (e.g. immediate store), !Fx, 0 <= x <= 255
Bit 7 - DEBUG_OUTPUT (In reading out RAM, it also edits @ -
Note : Not in the Page mode)
Bit 6 - Output of device address (DA) with <CR><LF> in front of every data record
Bit 5 - Resets the lightning-input once every day (Version 2.24 and later)
Bit 4 - Connection of serial Reinhardt-sensors to the GPS-input (Version 2.24 and later)
Bit 3 - ALTERNATIVE SENSORS (Version 2.13 and later)
(outputs alternative sensors (valuePort A and GPS-satellites) instead of the Standard-
sensors in position 31 (PW-FAIL WD) and 32 (PW-Fail)
Bit 2 - De-activates internal GPS-determination of local altitude
Bit 1 - Does not take local altitude from the GPS-receiver
Bit 0 - Immediate Store - Stores immediately after plugging in inspite of incorrect time
Example :
'!' 'F0' <#13> ;
Writes into the datalogger only after the clock is set
'!' 'F1' <#13> ;
Writes into the datalogger at once (incorrect time)
'!' 'F12' <#13> ;
Does not take local altitude from the GPS and outputs alternative sensors
Changing from measured value output and adjustment mode (output of frequency):
'!' 'W' <#13>
Fading in/out single sensors (All available sensors are listed on a following page.)
'!' 'KX,A0' <#13> ;
Sensor with output number X is not edited
'!' 'KX,A1' <#13> ;
Sensor output number X is edited
Sensor attenuation for turn sensor on / off
'!' 'KX,M0' <#13> ;
Sensor with output number X is not attenuated
'!' 'KX,M1' <#13> ;
Sensor output number X is attenuated