8 Technical appendix
8.1 Control Parameters for calibrating an additional sensor
PLEASE NOTE:
<#13> stands for ASCII-characater 13, i.e.CARRIAGE RETURN.
The command can also be closed with <#13><#10> (<CARRIAGE RETURN> - <LINE
FEED>, i.e. <CR><LF>).
Changing from measured value output and adjustment mode (voltage output):
'!' 'W' <#13>
Transmitting the linearisation data:
'
!' 'L' <SENSORNUMBER> ',' <INDEX : 1..6> ','
'F'
<VOLTAGE(mV)> <#13>
'!' 'L' <SENSORNUMBER> ',' <INDEX : 1..6> ','
'W'
<ANALOGVALUE> <#13>
E.g.: You measure 3054 V at 24.5 °C for additional sensor A in the 3rd position of your adjustment
table, it will look like this :
!L5,3,F3054 <#13>
!L5,3,W24.5 <#13>