7 Options
7.1 Switching outputs
The MWS 55 / 88 and sensors series 55 are also available with switching outputs.
The MWS 10 already contais this option!
These switching outputs can switch a contact (Photo-MOS relais) and a ground referred voltage
5VDC /100mA in dependence of measured values.
These contacts are accessible at a 4-pole connector.
On the following page you'll find an overview of the connectors of Sensors series 55 with switching
outputs.
These sensors are based onto the WSA (Warning signal alert).
Further details you'll find in the respective
.
The cable (option) for connecting the switching outputs has the following connections:
GND (Pin1) - grey
5VDC switched (Pin2) - pink
Switching contact 1 (Pin3) - green/yellow
Switching contact 2 (Pin4) - white/brown
The switching contact is controlled by the virtual sensor V9.
The switched 5VDC is controlled by the virtual sensor V10.
If, for example, the contact should be closed when wind speed exeeds 15 km/h, the following
command will perform this:
!V9,Term *?1:00!30"30 WG>15
The meaning of all parameters is as follows:
Close contact when WG>15; *(always); ?(at least 1min0sec); !(delay on 30sec); "(delay off 30sec).