PAGE 21
4 Error List
Error-No. Level
Description
Cause
Troubleshooting
100
24
no receiver is correctly con-
nected
- open wire between GPS-receiver
and GREEN FIT Controller
- fuse B6.1 or B6.2 defective
- no power at receiver
- check cables from GREEN FIT Con-
troller to GPS-receiver
- check fuses in the GREEN FIT Con-
troller
- check the signals from the GPS re-
ceiver to be evaluated (NMEA 0183,
NMEA 2000, J1939 GPS)
101
24
no reception of GPS signals
- wrong wires are connected
- wrong baudrate
- check cable between GPS-receiver
and GREEN FIT Controller
- check settings of GPS-receiver
102
24
poor reception of GPS signals
- no free view to the sky
- objects (trees, houses etc.) di-
sturb the reception
move to an open area
106
24
already receiving GPS signals,
but these need to be examined
GPS receiver has not yet properly
started
- Wait until the GPS receiver starts
properly
- move to an open area
114
24
message J1939 VP is not
received
wrong settings of the GPS-receiver
check the GPS-receiver settings
115
24
message J1939 VDS is not
received
wrong settings of the GPS-receiver
check the GPS-receiver settings
119
24
GPS receiver lost RTK quality
GPS receiver switched to lower gps
quality than RTK
check reference age
120
24
GPS receiver lost DGPS quality
GPS receiver switched to lower gps
quality as DGPS
check reference age
121
24
GPS update rate is
too slow
wrong settings of the GPS-receiver
check the GPS-receiver settings
1000
0
No signal from angle sensor.
- Short circuit in cable.
- Open wire in cable.
- Sensor is defective.
- Contacts of connectors are ope-
ned.
- Inspect angle sensor.
- Check cables from GREEN FIT Con-
troller to wheel angle sensor.
- If all connections are good, replace
wheel angle sensor.
- Check contacts of connectors.
1001
1
Angle sensor does not work
correctly.
- Axis is driven to block.
- Mechanism or suspension of
wheel angle sensor defective.
- A new wheel angle sensor was
assembled incorrectly.
- An obstacle prevents the move-
ment of the axis.
- Check mechanism of wheel angle
sensor.
- For new angle sensors, the sensor
has to be calibrated through the „te
-
ach-in“ page.
1002
0
Angle sensor – teach data
invalid.
-
Teach angle sensor.