REHM 1513230 Short Manual Download Page 4

 

 

General safety instructions 

The  system  was  developed  and  designed  by  the  generally  accepted  rules  of 
technology. 

 
• Safety  and  warning  instructions  serve  as  occupational  safety  and  accident  
   prevention. They must be observed. 

• Beside  the  advice  given  in  this  short  guide,  the  general  safety  and  accident  
   prevention regulations (in Germany, among others UVV BGV A3, TRBS 2131  
   and BGR 500 Chapter 2.26 (previously VGB 15): "Welding, cutting and allied  
   processes"  and  particularly  the  conditions  for  arc  welding  and  cutting  
   contained  therein  or  the  corresponding  national  regulations)  must  be  
   observed. 
 
• Also observe the safety information signs on the factory floor of the operator. 
 
• All safety instructions and warnings as well as the nameplate on / near the  
   system must be kept legible. 
 
• Safety equipment must never be dismantled or put out of operation as this will  
   result in dangerous hazards and the intended use of the system is no longer  
   guaranteed. The dismantling of safety devices for equipping, repairing and  
   maintenance is described in detail. The safety devices must be refitted  
   immediately on completion of such work. 
 
• Changes  to  the  system  or  the  mounting  or  incorporation  of  additional  
   equipment  as  well  as  the  decommissioning  of  safety  devices  are  not  
   permitted. Doing so will invalidate any warranty and liability claims. 

•  When using external aids and agents (for example, solvents for cleaning) the  
   user of the system is responsible for ensuring the safety of the unit. 

• REHM welding systems are, except when this is expressly stated in writing by  
   REHM, only for sale to commercial / industrial users and are only intended to  
   be used by commercial / industrial users.  
 

Technical data: 
 

-  Output current with electrode 140 A at a duty cycle of 100% (40°C) 
-  Output current with WIG 160 A at a duty cycle of 100% (40°C) 
-  Open circuit voltage from 85V 
-  Anti-stick function - no burn-out of the electrode if it accidentally sticks  
-  Protection type IP23 

 

 

Summary of Contents for 1513230

Page 1: ...GB REHM SCHWEISSTECHNIK BOOSTER PRO 230 Electrode inverter SHORT GUIDE...

Page 2: ...te of issue 17 08 2020 REHM GmbH u Co KG Uhingen Germany 2020 The content of this description is the property of Rehm GmbH u Co KG The copying and distribution of this document its use and communicati...

Page 3: ...iption 5 3 Operation description 6 3 1 Overview oft he operating panel 6 3 2 Operation in the main menu Menu 1 7 3 3 Current curve Menu 2 8 3 4 Settings Menu 3 10 4 Circuit diagram 11 5 Maintenance wo...

Page 4: ...n dangerous hazards and the intended use of the system is no longer guaranteed The dismantling of safety devices for equipping repairing and maintenance is described in detail The safety devices must...

Page 5: ...alia DIN EN60974 10 2008 09 Annex A Qualification of the operating personnel REHM welding systems should be operated only by persons who are trained and instructed in the use and maintenance of weldin...

Page 6: ...f controls 6 Drawer storage for electrodes gas nozzles etc 2 Control panel push and rotate knob 7 Main switch On Off 3 Current socket negative TIG TIG welding torch Electrode Workpiece or electrode ho...

Page 7: ...reen Operation via rotary encoder with push button Fig 2 Push and rotary encoder Rotary encoder with push knob Moves the pointer cursor on the screen clockwise or counter clockwise Positions reached a...

Page 8: ...l has to be set Display of the welding function Procedure Boost Explanation Rutile electrode No with fuse hold Basic electrode No with fuse hold Rutile electrode Yes Basic electrode Yes WIG LiftArc Th...

Page 9: ...ctive Pulse current I1 is the current displayed on the main screen Menu1 which can also be adjusted from there When time pulses occur current I1 is only present for time t1 and then changes to current...

Page 10: ...lse On Off If the symbol is displayed in blue the time pulse is activated in black it is deactivated If the pulse is inactive the I2 display goes out HYPER PULSE On Off If the symbol is displayed in b...

Page 11: ...rc Software version of the machine Power control Software version of the operation The fuse limitation can be activated or deactivated here Limits the maximum adjustable current Setting Electrode max...

Page 12: ...11 4 Circuit diagram...

Page 13: ...result in operating faults Periodic maintenance of the system is therefore essential No constructive change or additions may be made to the system 5 2 Maintenance table The maintenance intervals are r...

Page 14: ...y requirements for arc welding units in accordance with the following product standards EN 60974 1 2018 12 Arc welding equipment Part 1 Welding current source EN 60974 3 2015 12 Arc welding equipment...

Page 15: ...14...

Page 16: ...Stand 08 2020 Artikel Nr 7302157...

Reviews: