REGIS T-X-B – Access or time and attendance controller
10/2016
Black line
www.jantar.si
REGIS T-X-B – ACCESS or TIME AND
ATTENDANCE CONTROLLER
The Regis is a controller with built-in proximity card reader and 7”
LCD capacitive touch screen display. It is designed for residential
and business buildings, offices, shops, etc. The controller can have
125kHz or 13.56MHz reading frequency.
The entire set-up procedure is carried out with the software. The
controller allows access for up to 30000 users and saves 100000
events. If you bought the controller in time and attendance kit,
then inputs and outputs cannot be controlled.
It can also be used as a Wiegand 26-bit reader, if needed.
The SDK is also available for this controller. If a user or software
producer wants to develop its own application, please contact us.
TECHNICAL DATA
REGIS T-X-B
REGIS T-1-B reading frequency
125kHz
REGIS T-1-B reading distance
Up to 15cm
REGIS T-1-B current consumption in
standby mode
300mA
REGIS T-1-B reading field in vertical
position
Bottom side of
the controller
REGIS T-1-B reading field in horizontal
position
Right side of the
controller
REGIS T-3-B reading frequency
13.56MHz
REGIS T-3-B reading distance
Up to 7cm
REGIS T-3-B current consumption in
standby mode
330mA
REGIS T-3-B reading field in vertical
position
Bottom side of
the controller
REGIS T-3-B reading field in horizontal
position
Right side of the
controller
Dimensions (mm)
210x150x35
(WxHxD)
Protection
IP21
Operating voltage
From 9V to 14V DC
Operating temperature
From -20°C to 60°C
Connector
2x 8pin, 1x ethernet
Display
TFT - capacitive touch
Tamper
Accelerometer
Display resolution
1024 x 600
Humidity
10-80%, non condensing
Memory
30000 cards or codes
100000 events
Inputs
Door status
Push button
Outputs
Transistor output for el. strike
0.5A
Clock
Real time clock, battery backup
(max. ten hours)
Communication
RS485
Ethernet
Keypad
Configurable buttons
Selectable colors
*if Regis T is in Spider mode, the same data applies
Power supply
The controller need’s external power supply to operate. The Spider
W40 power supply is sufficient to power two controllers and two
12V electric strikes or two 12V magnetic locks (0.5A). If you will
use it as a standalone controller and low consumption electric
strike (0.25A) you can use power supply Spider W5.
Voltage drops and cable signal interferences
When you connect the controller, use cable with a diameter of at
least 0.22mm
2
. If the cable length exceeds 25m, use one twisted
pair of UTP cables for the positive (+) pole and one for the
negative (-) pole. The cable length between power supply and the
controller should not exceed 50m.
Take into consideration that a 0.22mm
2
cable has a resistance of
approximately 9 ohm per 100m. The power supply at the end of
cable should be a minimum of 9V. If you are using el. strike, it is
highly recommended that the voltage drop is calculated. At greater
distances, a thicker cable of 0.5mm
2
or more should be used
wherever possible.
If the load is, for example, 0.5A (with el. strike) then, on the
0.22mm
2
cable voltage drop will be 4.5V at 100m. For the device
with 60mA consumption, the voltage drop is 0.5V.
Reading distance depends on where the controller is installed. The
presence of metal or interferences can significantly reduce the
reading distance.
DO NOT
install the controller directly on metal
surfaces and/or cover it with a metal cover.
It is
not recommended
to install controllers closer than
30cm
from each other in any direction. Otherwise, it may result in
inaccurate readings or, indeed, in the controller
not reading at
all
.
For the Regis T-3-B to comply with EMC directives (CE), you
have to put ferrite core on the cable as close to the
controller as possible, making two turns!
CONNECTOR DESCRIPTION
Connectors are marked on the housing
with 1 in 2. First contact on both
connectors starts on the marked side (1
and 2)
CONNECTOR 1 – connection of power supply, el. strike...
Contact
Description
Specification
1
9-14V DC
Power supply
2
GND
Ground
3
El. strike output
Max. 0,5A
Active = GND
4
Alarm output
Max. 0,5A
Active = GND
5
Door status switch input
Active = GND
6
Push button input
Active = GND
7
CA
RS485 A line
8
CB
RS485 B line
CONNECTOR 2 – connection of external reader
Contact
Description
Specification
1
9-14V DC
Power supply
2
GND
Ground
3
Data 0
Wiegand protocol
4
Data 1
Wiegand protocol
5
Buzzer output
Active = GND
6
LED output
Active = GND
7
XA – for protocol reader
RS485 XA line
8
XB – for protocol reader
RS485 XB line