INSTALLATION INSTRUCTIONS
ALL CONNECTIONS TO BE CARRIED OUT BY A QUALIFIED ELECTRICIAN
ALL CONNECTIONS TO BE CARRIED OUT BY A QUALIFIED ELECTRICIAN
1
PLEASE READ CAREFULLY BEFORE STARTING INSTALLATION.
PLEASE READ CAREFULLY BEFORE STARTING INSTALLATION.
Regent Lighting reserves the right to change specifications modify designs and discontinue items without incurring obligation and
whilst every effort is made to ensure that descriptions, specifications and other information in this catalogue are correct, no
warranty is given in respect thereof and the company shall not be liable for any error therein.
WARNING:
TO AVOID FIRE, SHOCK OR DEATH
TURN OFF POWER
AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING
ALL LUMINAIRES SUPPLIED AND TO BE INSTALLED ABOVE AND BELOW 5 METERS ARE IN COMPLIANCE WITH SANS
60598 SECTION 3.5.6 ACCORDING TO THE MANUFACTURER GUARANTEE AND WARRANTY
Electrical products can cause death, injury, or damage to property. Installation of this product
must be carried out by a qualified electrician, in compliance with SANS 10142 or corresponding
regulations of the country of installation. On completion of installation, the Certificate of
Compliance must be updated.
WARNING
Electronic Control Device
Electronic Control Device
WARNING
3 - 13 MAIN REEF SERVICE ROAD, CORNER
SPRINGBOK AND MAIN REEF ROAD, INDUSTRIA,
JOHANNESBURG. SOUTH AFRICA.
TEL : +27 11 474 0171
www.regentlight.co.za
REGENT LIGHTING A DIVISION
OF WAHL INDUSTRIES.
Save These Instructions for Future Reference
ELECTRIC SHOCK
HAZARD
This equipment is to be
serviced by trained
personnel only.
ELECTRIC SHOCK
HAZARD
This equipment is to be
serviced by trained
personnel only.
Longo
DO NOT CONNECT THE FITTING LIVE
March 2018
For non replacable lightsources:
The light source of this luminaire is not replaceable; when the
light source reaches its end of life the whole luminaire shall be replaced
92MM
Product installed finished
with conduit drainage
FFL / Tiled Surface
Grout
Concrete
Drain
Product installed finished
with gravel drainage
Requirements:
Be sure the electricity to the system you are working on is isolated.
If the main supply power (live) is on, it will cause damage to the luminaire.
1. Select required position.
Create a cavity with drainage for fitting in the ground/paving at the required position.
The total height of the product is 92mm and
SHOULD
be level with the
FINISHED floor level
- FFL (the tiled surface)
.
*NB: GRAVEL FOR DRAINAGE - Lay at least 150mm of gravel beneath the well of the cavity
and check drainage efficiency.
Ensure there is a drain under the gravel when installing the fitting into paving or cement.
92MM
FFL / Tiled Surface
Grout
Concrete
Gravel
DO NOT PLUG
(CONNECT) WHEN
LIVE AS IT WILL CAUSE
DAMAGE TO THE
LUMINAIRE.
9
9. Place the fitting into the aluminium extrusion.
Connect to main supply using the electrical tail
supplied from the fitting.
Ensure the fitting is secure in the aluminium
extrusion.
Fitting
Electrical
tail
Mains to
Luminaire
Earth Loop
Green/Yellow
Switch
Live Red
Neutral loop
Black or Blue
(L) Brown
(E) Green/Yellow
(N) Blue
DO NOT PLUG
(CONNECT) WHEN
LIVE AS IT WILL CAUSE
DAMAGE TO THE