Requirements:
Be sure the electricity to the system
you are working on is isolated.
If the main supply power (live) is on, it
will cause damage to the luminaire.
1. Select the required position for the
luminaire, towards the pathway.
A.
Ensure the electrical cable is fed through
the mounting hole where the bollard will be
installed.
B.
Insert the bolt cage into the mounting
hole and feed the electrical cable through
the bolt cage towards the surface, ensuring
the cable is fed parallel to the pathway.
B
Ground Level
1
2
www.regentlight.co.za
www.regentlight.co.za
INSTALLATION INSTRUCTIONS
ALL CONNECTIONS TO BE CARRIED OUT BY A QUALIFIED ELECTRICIAN
ALL CONNECTIONS TO BE CARRIED OUT BY A QUALIFIED ELECTRICIAN
1
PLEASE READ CAREFULLY BEFORE STARTING INSTALLATION.
PLEASE READ CAREFULLY BEFORE STARTING INSTALLATION.
Regent Lighting reserves the right to change specifications modify designs and discontinue items without
incurring obligation and whilst every effort is made to ensure that descriptions, specifications and other
information in this catalogue are correct, no warranty is given in respect thereof and the company shall not be
liable for any error therein.
WARNING:
TO AVOID FIRE, SHOCK OR DEATH
TURN OFF POWER
AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING
ALL LUMINAIRES SUPPLIED AND TO BE INSTALLED ABOVE AND BELOW 5 METERS ARE IN COMPLIANCE WITH SANS
60598 SECTION 3.5.6 ACCORDING TO THE MANUFACTURER GUARANTEE AND WARRANTY
Electrical products can cause death, injury, or damage to
property. Installation of this product must be carried out by a
qualified electrician, in compliance with SANS 10142 or
corresponding regulations of the country of installation. On
completion of installation, the Certificate of Compliance must
be updated.
Bedford Bollard - Plinth Mounted
Electronic/Magnetic Control Device
WARNING
Electronic/Magnetic Control Device
WARNING
3 - 13 MAIN REEF SERVICE ROAD, CORNER
SPRINGBOK AND MAIN REEF ROAD, INDUSTRIA,
JOHANNESBURG. SOUTH AFRICA.
TEL : +27 11 474 0171
www.regentlight.co.za
REGENT LIGHTING A DIVISION OF WAHL
INDUSTRIES.
DO NOT CONNECT THE FITTING LIVE
December 2017
Save These Instructions for Future Reference
Save These Instructions for Future Reference
ELECTRIC SHOCK
HAZARD
This equipment is to be
serviced by trained
personnel only.
ELECTRIC SHOCK
HAZARD
This equipment is to be
serviced by trained
personnel only.
Bedford Bollard - Plinth Mounted
LIGHT_5
11,1,1
0-1
-1
LIGHT_6
11,1,1
0-1
-1
Clear diffuser
with louvre
Bedford Dome
LIGHT_5
11,1,1
0-1
-1
LIGHT_6
11,1,1
0-1
-1
Opal diffuser
with louvre
LIGHT_5
11,1,1
0-1
-1
LIGHT_6
11,1,1
0-1
-1
LIGHT_5
11,1,1
0-1
-1
LIGHT_6
11,1,1
0-1
-1
LIGHT_5
11,1,1
0-1
-1
LIGHT_6
11,1,1
0-1
-1
LIGHT_5
11,1,1
0-1
-1
LIGHT_6
11,1,1
0-1
-1
Clear diffuser
with louvre
Opal diffuser
with louvre
Bedford Cone
Clear diffuser
with louvre
Opal diffuser
with louvre
Bedford Flat
Ground Level
A
BOLT CAGE ORIENTATION
PATHWAY/LIGHT SOURCE DIRECTION
SERVICE/ACCESS DOOR DIRECTION
LIGHT_5
11,1,1
0-1
-1
LIGHT_6
11,1,1
0-1
-1