INSTALLATION
CONVERSION FROM LP TO NG
1.
Remove thermocouple shield and inner tray by removing 5 screws in loca-
tions shown below in Diagram 1.
2.
Remove outer tray by removing 8 screws in locations shown below in
Diagram 2.
3.
Slide burner away from orifi ce and remove as shown below in Diagram 3.
Thermocouple
shield
Inner tray
Diagram 1
Diagram 2
Diagram 3
Turn the unit off and allow to cool to room temperature.
Remove leaf cover, glass crystals, rocks or logs if installed.
Remove Table Top - see instructions in this manual.
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION !!
Each Kit contains one NG Conversion Kit
Conversion Kit # 286-968 Contains:
Qty. Part
#
Description
1
904-688
Burner Orifi ce #31
1
938-529
Yellow "NG" label
1
909-265
MAX 0.5 PSI label
1
286-035
Regulator mounting base
1
286-036
Regulator mounting top
1 910-053 Regulator
NG
1
904-978
3/8” Flex pipe black 18” length
4 904-553 #8
Philips
1 919-227 Instruction
Sheet
5
. Adjust aeration setting to fully closed for NG.
4.
Remove LP orifi ce #50—replace with NG orifi ce #31.
Diagram 4
Diagram 5