Regency P36D-LP10 Owners & Installation Manual Download Page 1

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.  6988 Venture St., Delta, BC  Canada, V4G 1H4

919-444a

07.14.15

P36D  Zero  Clearance

Direct  Vent  Gas  Fireplace

Owners & Installation Manual

Tested by:

Installer

: Please complete the details on the back cover 

and leave this manual with the homeowner.

Homeowner:

 Please keep these instructions for future reference.

MODELS:    P36D-NG10 Natural Gas     P36D-LP10  Propane

www.regency-fire.com

 

-  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 

appliance. 

- WHAT TO DO IF YOU SMELL GAS

 • 

Do not try to light any appliance.

  •  Do not touch any electrical switch: do not use any phone in your building.

    Leave the building immediately.

  •  Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's 

 

instructions.

  • If you cannot reach you gas supplier, call the fire department.

   

  Installation and service must be performed by a qualified installer, service agency or the gas supplier.

     WARNING

FIRE OR EXPLOSION HAZARD

F

ailure to follow safety warnings exactly could result in serious

injury, death, or property damage.

 

Summary of Contents for P36D-LP10

Page 1: ...other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach you gas supplier call the fire de...

Page 2: ...been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch The model P36D 10 has been approved by Intertek for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many featu...

Page 3: ...anufacturer s installation instructions and local codes if any In the absence of local codes follow the current National Fuel Gas Code ANSI Z223 1 and the current National Electrical Code ANSI NFPA 70 in the U S A and the current CAN CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22 1 in Canada ThisFPI Mobile ManufacturedHomeListedappliancecomes factory equipped with ...

Page 4: ...rner Assembly Log Set 60 Vignette faceplate and finishing trim 61 Warranty 63 Copy of Safety Decal for P36D 10 5 MA Code CO Detector 6 Unit Dimensions with vignette faceplate 7 Unit Dimensions with vignette vignette finishing trim 8 Unit Dimensions with safety screen 515 929 and op tional louvers 8 Before You Start 9 Important Message 10 General Safety Information 10 Installation Checklist 10 Loca...

Page 5: ...yer au gaz à évacuation For use with glass doors certified with the appliance only Pour utilisation uniquement avec les portes en verre certifiées avec l appareil Made in Canada Fabrique au Canada FPI Fireplace Products International Ltd Delta BC Canada APPAREIL FONCTIONNANT AU GAZ PROPANE CONCU POUR ETRE POELE Modéle P36D LP10 Pression d allimentation minimum Pression à la tubulure d chappement l...

Page 6: ...grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless up...

Page 7: ...Regency P36D 10 Zero Clearance Direct Vent Gas Fireplace 7 7 installation UNIT DIMENSIONS WITH VIGNETTE FACEPLATE Optional 3 sided finishing trim not shown 38 W x 33 3 4 H ...

Page 8: ...8 Regency P36D 10 Zero Clearance Direct Vent Gas Fireplace 8 dimensions UNIT DIMENSIONS WITH VIGNETTE AND VIGNETTE FINISHING TRIM UNIT DIMENSIONS WITH SAFETY SCREEN 515 929 AND OPTIONAL LOUVERS ...

Page 9: ...TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES WARNING FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE YOUNG CHILDREN SHOULD BE CARE FULLY SUPERVISED WHENTHEY ARE IN THE SAME AREA AS THE APPLI ANCE TODDLERS YOUNG CHILDREN AND OTHERS MAY BE SUSCEPTIBLE TO ACCIDENT...

Page 10: ...uld this appliance be modified Parts that have to be removed for servicing should be replaced prior to operating this appliance 12 Installation and any repairs to this appliance should be done by a qualified service person A professional service person should be called Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer birth defects or other...

Page 11: ...allationswhenusedwithaListedMillivolt Thermostat Some areas may have further requirements check local codes before installation 6 The P36D 10 Direct Vent Gas Fireplace is approvedforalcoveinstallations whichmeet the clearances listed on the next page 7 Werecommendthatyouplanyourinstallation on paper using exact measurements for clearances and floor protection before actually installing this applia...

Page 12: ...ce and vent system be installed only in accordance with these instructions Clearance to Combustibles from Back 0 0mm Side 0 0mm Floor 0 0mm NOTE The minimum floor clearance must be maintained from the top surface of the carpeting tile etc Minimum Clearance from Top of Unit to Ceiling from top of unit 32 1016mm Side Wall Clearances 6 152mm Measured from edge of unit See Regency Clearances section f...

Page 13: ...rect Vent Gas Fireplace 13 13 installation Min 6 152mm 30 1 2 775mm Top of Unit Min 32 1016mm to Ceiling CLEARANCES MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram Maximum 1 1 2 projection at 2 minimum clearance ...

Page 14: ...ishing trim 37 1 2 must be non combustible if a lower mantel is desired Note Ensure the paint that is used on the mantel and the facing is heat resistant or the paint may discolour MANTEL CLEARANCES WITH VIGNETTE VIGNETTE FINISHING TRIM STEPPED FINISH MANTEL CLEARANCES WITH VIGNETTE VIGNETTE FINISHING TRIM FLUSH FINISH MANTEL CLEARANCES WITH SAFETY SCREEN AND LOUVERS Vignette finishing trim steppe...

Page 15: ...e to the same degree as the rest of the house apply vapour barrier and drywall as per local instal lation codes Do not insulate the fireplace itself 4 The top of the unit must not be closer than 32 813mm to the ceiling 3 8 1 3 82 mm 2 37 7 16 951mm Non combustible Material supplied Steel stud on edge 2nd Steel stud on edge install after unit in place 12 305mm Wood stud Wood stud Drywall Diagram 1 ...

Page 16: ...D 36 1 4 37 1 4 17 3 8 46 921mm 946mm 441mm 1168mm D isMinimumheighttocombustiblematerials includingtheMinimum2 51mm Topclearance to the Horizontal Vent Diagram 1 Diagram 3 Diagram 5 Diagram 6 Diagram 2 Diagram 4 B Steel stud on edge A C D Minimum Height to Combustible Material B Steel stud on edge A C D Minimum Height to Combustible Material B Steel stud on edge A C D Minimum Height to Combustibl...

Page 17: ...pening Rough edges will be visible from the front view with the Vignette faceplate if not using the optional finishing trim To maintain a clean finished edge it is recommended to install the combustible facing material with the finished edge against the fireplace nailing strips Alternatively you can use J Style Trim or Metal Corner Bead to cover cut edges of the non combustible facing material Dia...

Page 18: ...tage junction box to the framing at desired location within 10 ft from fireplace 2 Feed the 12 pin connector through the opening at back of junction box 3 Connect the 12 pin connector to the back of the receiver 4 Install the Receiver in the Low Voltage Junction box 5 Insert the 4 AA type batteries in the battery compartment with the correct polarity 6 Place the slider into the cover plate 7 Put t...

Page 19: ...nce The gas appliance and vent system must be vented directly to the outside of the building and never be attached to a chimney serving a separate solid fuel or gas burning appliance Eachdirectventgasappliancemustuseit sown separate vent system Common vent systems are prohibited NAILING STRIPS Determine the total thickness of facing material e g noncombustibleplusceramictiles toallow the finished ...

Page 20: ... line extended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway located ...

Page 21: ...um run of 4 feet 1 6 7 8 dia flexible liner 4 ft length 2 4 dia flexible liner 4 ft length 3 spring spacers 4 4 thimble 2 5 AstroCap termination cap 1 6 screws 12 7 tube of Mill Pac 1 8 plated screws 8 9 screws 8 x 1 1 2 Drill Point Stainless Steel 4 1 6 7 8 dia flexible liner 10 ft length 2 4 dia flexible liner 10 ft length 3 spring spacers 7 4 thimble 2 5 AstroCap termination cap 1 6 screws 12 7...

Page 22: ...Adjustable Length 7 Black N A N A 4D7AB N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A Extension Pipe 8 1 2 Black 46DVA 08AB N A N A N A N A N A Adjustable Length 12 Galvanized N A N A 4D12A N A SV4LA12 TC 4dLSI Adjustable Length 12 Black N A N A 4D12A N A SV4LBA12 TC 4dLSIB Extension Pipe 16 Galvanized 46DVA 16A N A N A N A N A N A Extension Pipe 16 Black 46DVA 16AB N A...

Page 23: ...ontal Termination Kit A Disc 4DT HKA 4DHTK2 4DHTKA SV SHK TM4 HTK Horizontal Termination Kit B 46DVA KHA Changed Components 4DT HKB 4DHTK1 4DHTKB SV HK TM4 HTK Vertical Termination Kit Disc 4DT VKC 4DHTK 4DHTK SV FK N A FPI 946 506 P Vent Guard Optional for AstroCap 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all rigid piping 946 208 P Vent Guard Op...

Page 24: ...nches The FPI AstroCapTM and FPI Riser Vent terminal are certified for installations using FPI venting systems as well as Simpson Dura Vent Direct Vent American Metal Products Security Secure Vent AmeriVent Direct Vent AstroCapTM is the proprietary trademark of FPI Fireplace Products International Ltd Dura Vent and Direct Vent are registered and or proprietary trademarks of Simpson Dura Vent Co In...

Page 25: ...d pipe adaptor Part 510 994 when using Rigid Pipe venting systems All Rigid Pipe Systems 4 inner diameter 6 5 8 outer diameter FPI Flex Vent 4 inner diameter 6 7 8 inner diameter Maintain clearances to combustibles Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall A vent guard should be used whenever the termination is low...

Page 26: ...tain clearances to combustibles Note Must use optional rigid pipe adaptor when using rigid vent systems Part 510 994 VENTING ARRANGEMENTS VERTICAL TERMINATION RIGID PIPE SYSTEM Propane Natural Gas The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations using two 90o elbow with rigid pipe vent systems for Propane and Natural Gas ...

Page 27: ...s per the diagram 1 The shaded area in the diagram 1 shows all allowable combinations of straight vertical and offset to vertical terminations with rigid pipe vent systems for Propane and Natural Gas Maximum two 45o elbows allowed Vent must be supported at offsets Firestops are required at each floor level and whenever passing through a wall Maintain clearances to combustibles Diagram 1 ...

Page 28: ...ontal Please note minimum 1 foot between 90o elbows is required One 90o elbow Two 45o elbows Lengths do not include elbow indicated Option V H V V1 H H1 A 0 Min 1 Max 1 Min 2 Max B 1 Min 2 Max 3 Min 3 Max C 2 Min 2 Max 5 Min 4 Max D 3 Min 2 Max 7 Min 5 Max E 4 Min 3 Max 9 Min 6 Max F 5 Min 4 Max 10 Min 7 Max G 6 Min 5 Max 11 Min 8 Max H 7 Min 6 Max 12 Min 9 Max With these options max total pipe le...

Page 29: ... and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required One 90o elbow Two 45o elbows Lengths do not include elbow indicated V H1 H V1 Option V H H1 V V1 A 0 Min 2 Max 2 Min B 1 Min 2 Max 3 Min C 2 Min 3 Max 4 Min D 3 Min 4 Max 6 Min E 4 Min 5 Max 7 Min F 5 Min 6 Max 8 Min G 6 Min 7 Max 9 Min H 7 Min 8 Max 10 Min With these options max total pipe length is 30 feet wit...

Page 30: ...d unnecessary bending The Air Intake pipe must be attached to the inlet air collar of the termination cap Required Parts Part Description 946 529 Co linear DV Vertical Termination Cap 948 305 3 Flex 35 ft 946 563 Co Axial to Co Linear Adapter Kit whichcontainsthefollowing Co linear Flex Adapter Outer Pipe Inner Pipe Adapter 510 994 Rigid Pipe Adaptor FPICabinetand orFlatWallMantlesmay be used in t...

Page 31: ... VENTING ARRANGEMENT VERTICAL TERMINATIONS CO LINEAR FLEX SYSTEM INTO MASONRY FIREPLACES FOR BOTH RESIDENTIAL MANUFACTURED HOMES The shaded area in the diagrams show the allowable vertical terminations 8 Min 40 1 2 30 Max 30 Horizontal Distance Feet Vertical Height feet 2 max ...

Page 32: ...gram 3 Diagram 3a Note Riser Vent is only for use in above grade terminations NOTE For best results and optimum perfor mance with each approved venting system it is highly recommended to apply Mill Pac sealant supplied to every inner pipe connection Failure to do so may result in drafting or performance issues not covered under warranty Note With Dura Vent the minimum h e i g h t i s achieved by i...

Page 33: ...location Diagram 1 wheretheventwillpenetratetheceiling Drill a small hole at his point Next drop a plumb bob from the roof to the hole previously drilledintheceiling andmarkthespotwhere the vent will penetrate the roof Determine if ceilingjoists roofraftersorotherframingwill obstruct the venting system You may wish to relocate the appliance or to offset asshown in Diagram 2 to avoid cutting load b...

Page 34: ...DIRECT VENT SYSTEM FLEX INSTALLATION PROCEDURES 1 Locate the unit in the framing rough in the gas preferably on the right side of the unit and the electrical Junction block is on the left side on the left Locate the centerline of the termination and mark wall accordingly Cut a 10 254mm hole in the wall inside dimension Note A 1 1 2 38mm clearance around the liner must be maintained except that onl...

Page 35: ...nnectors are usually considered to meet this requirement Important Always check for gas leaks with a soap and water solution or gas leak detec tor Do not use open flame for leak testing HIGH ELEVATION This unit is approved in Canada for altitude 0 to 4500 ft CAN1 2 17 M91 with the orifice supplied P36D NG10 System Data For 0 to 4500 feet altitude Burner Inlet Orifice Sizes 37 Max Input Rating 30 0...

Page 36: ...ifoldpressureiscontrolledbyaregulator built into the gas control and should be checked at the pressure test point Note To properly check gas pressure both inlet and manifold pressures should be checked using the valve pressure ports on the valve 1 Make sure the valve is in the OFF position 2 Loosen the IN and or OUT pressure tap s turning counterclockwise with a 1 8 wide flat screwdriver 3 Attach ...

Page 37: ...ner Orifice 52 1 904 529 5 32 Allen Key 1 918 590 Decal Converted to LPG 1 908 528 Red LPG label 1 910 037 LPG Injector Pilot Orifice 1 910 582 Stepper Motor 1 919 472 Instruction Sheet Installation of LPG Conversion Kit 10 Remove NG stepper motor by removing 3 screws in locations shown below re place with LP stepper motor secure in place with 3 screws Remove NG Stepper motor and replace with LP S...

Page 38: ...Insert the back brick panel first by carefully slipping it between the back wall of the firebox and the rear log bracket 4 Put the side panels in next Slide them in from the front and push them flat up against the wall Be very careful not to scratch them on the firebox hardware 4 Install the 2 brick retaining clips one on each side Note If the bottom brick panel must be removed Remove the Rear Log...

Page 39: ...lot operation The gas log kit Part 780 930 contains the following pieces a 02 75 Rear Log b 02 55 Middle Left Log c 02 50 Front Left Log d 02 53 Center Left Log e 02 51 Front Bottom Log f 02 54 Center Right Log g 02 52 Middle Right Log h 902 156 Embers i 902 179 Vermiculite j 946 669 Platinum Embers supplied with packaged manual NOTE If you will be installing the optional Brick Panels P36D P90 onl...

Page 40: ...ner tray and rest the log on the cutout on Log 02 53 Cutouts 5th Grate Tab 02 54 0 2 5 3 02 51 6 Position Log 02 54 across the cutouts in Logs 02 51 and 02 53 The notch in the bottom right end fitting against the 5th grate tab 5 Position Log 02 53 across the cutouts in Logs 02 75 and 02 51 with the notch on the left side of the log fitting into the 2nd grate tab Cutouts 2nd Grate Tab 02 53 02 75 0...

Page 41: ... 52 Rear Grate Tab 02 52 02 51 02 54 02 52 02 54 8 Place Log 02 52 between Logs 02 51 and 02 75 and on the indentation on Log 02 54 The bottom right end sits behind the rear grate tab Front Brackets Notch 02 50 02 53 02 50 02 55 02 53 9 Sit Log 02 50 on the front left side of the burner Push the back of the log against the 2 front brackets with the notch on the bottom of the log fitting into the f...

Page 42: ...ceonthefrontburneron and around the embers Avoid stacking platinum embers Platinum embers may be placed over burner ports 11 Test fire to ensure proper light off make sure flame flows smoothly from one end of burner to the other If there is any flame hesitation check that area for any blockage of the burner ports Do not block the burner ports in this area adjacent to the Log 02 54 02 51 02 54 IMPO...

Page 43: ...ly is needed for the fan blower operation Do not cut the ground terminal off under any circumstances NOTE Even if the fan is not purchased with the unit it is still a good idea to bring power to the receptacle box provided with the unit in case the fan is installed at a later date Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges CAUTION Labelallwires prior ...

Page 44: ...re below CAUTION Do not wire Thermostat wires to 120V wire 4 Connect the other thermostat lead to male connector disconnected from Step1using a female spade connector see picture below When complete turn remote receiver to the ON position Unit will now operate using the wall thermostat NOTE When the remote receiver is set to ON position the remote control transmitter and all of its features are no...

Page 45: ...fer to wiring diagram 5 Slide the thermodisc cover assembly on to the bracket clip on the underside of the firebox Thermodisc Clip 6 Install the Fan Control Module FCM on the base of the unit to the left of the gas valve Plug the FCM into the outlet 7 Plug in the fan power cord to the Fan Control Module into the outlet marked Fan Plug the FCM COM wire from the remote control wiring harness into th...

Page 46: ...ram 2 The standard flush door comes with a black frame To install the frame simply hook the top door flange onto the top of the unit and swing the door towards the unit see diagram 1 Be careful that the glass gasket does not roll up there must be a gap between the gasket and the door lip to ensure that the door sits securely on the unit see Diagram 2 Diagram 1 STANDARD FLUSH DOOR To remove the flu...

Page 47: ...ostat but any 250 750 millivolt rated non anticipator type thermostat that is CSA ULC or UL approved may be used Recommended Maximum Lead Length Two Wire When Using Wall Thermostat CP 2 System Wire Size Max Length 14 GA 50 Ft 16 GA 32 Ft 18 GA 20 Ft 20 GA 12 Ft 22 GA 9 Ft Thermostat Wire Table Install the supplied battery into the DC Sparker Box by opening the battery compartment NOTE The battery ...

Page 48: ...and safety screen installation 1 Hook the outer Vignette frame onto the unit Brackets on the frame hook on to tabs in the unit Note Use the inner slots for the P36 P36E units and the outer slots for the P36D P36D P36 P36E Tab Slot 2 Slot the tabs on the inner Vignette frame with safety screen into the corresponding slots in the outer Vignette frame as shown below ...

Page 49: ...all 3 Position the Inlay so it is exactly centered from side to side and top to bottom within the Inner Vignette Frame 4 With the top of the Inlay in correct position push the studs at the bottom of the Inlay through the actual screen NOTE Ensure Inlay is in correct position before pushing studs through the safety screen 5 Secure the Inlay in position with supplied brackets washers and nuts as sho...

Page 50: ...box side 2 Secure with 2 screws each side 3 Loosen the 3 screws in the top inside edge of the firebox 4 Slide the Finishing Trim Top over the Side Trim pieces and fit the bottom bracket slots over the screws Tighten the 3 screws to secure 5 Hook Vignette Faceplate brackets into place 7 Hook Vignette Faceplate brackets into place see specific instruc tions in unit manual 6 Install the lower finishi...

Page 51: ...e side trim with the holes in the firebox side 2 Secure with one screw per side on top the bottom screw is installed after the Vignette faceplate bracket is in place P33 P33E only 3 Loosen the 3 screws in the top inside edge of the firebox 4 Slide the Finishing Trim Top over the Side Trim pieces and fit the bottom bracket slots over the screws Tighten the 3 screws to secure 5 Hook Vignette Facepla...

Page 52: ...nd place the hook through both the glass door and the screen frame 3 To remove reverse steps OPTIONAL FLUSH LOUVERS INSTALLATION USED WITH SAFETY SCREEN 515 929 1 Install the top louver by sliding the two bracket clips into the brackets located underneath the top of the firebox 2 The bottom louver has a hinge that is attached 2 screws per hinge to the lip on bottom of the unit Note Top and bottom ...

Page 53: ...om ON to Remote or OFF IMPORTANT The remote control system sup plied with this appliance has several options for starting operating the appliance please readtheremotecontroloperatinginstructions packed with remote control to understand how to operate this remote system Option to download remote functions video with QR code below Proflame video LIGHTING PROCEDURE Important If the pilot does not hol...

Page 54: ...cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas à la lettre les instructions dans la présente notice risquede déclencher un incendie ou une explosion entraînant des dommages des blessures ou la mort Une in...

Page 55: ...ss FIRST FIRE The first fire in your fireplace is part of the paint curing process To ensure that the paint is properly cured it is recommended that you burn your fireplace for at least four 4 hours the first time you use it with the fan on When first operated the unit will release an odour caused by the curing of the paint the burning off of any oils remaining from manufacturing Smoke detectors i...

Page 56: ...aycreate carbon build up and will severely alter the unit s performance which is not covered under warranty THERMOPILE THERMOCOUPLE 1 Remove faceplate safety screen and glass door 2 Remove Logs and burner if installed 3 Remove rear log tray by removing 2 screws 4 Removepilotassemblybyremoving2screws 5 Pull pilot assembly up slightly and loosen the thermocouple or thermopile with a 7 16 wrench 6 Lo...

Page 57: ...ouvers 18 Fire up the unit again and check for proper flame appearance and glow on logs REMOVING VALVE 1 Shut off the gas and electrical supply 2 Remove the faceplate 3 Remove the safety screen and glass door 4 Remove the logs 5 Remove the burner grate assembly by remov ing the two screws and then lift the burner assembly out Diagram 1 Remove the left and right screws and then lift out the burner ...

Page 58: ...Brick Panel Back 34 Brick Panel Left 35 Brick Panel Right 511 031 Brick Clips each Part Description Burner 438 917 FanAssembly 120V 42 910 331 P Fan Motor 120 V 50 510 994 Rigid Pipe Adaptor 946 556 Heat Wave Duct Kit Optional 89 946 004 Junction Box 90 946 000 Round Duct Adaptor 91 946 002 Round to Oval Adaptor 92 946 001 Oval Duct Adaptor 93 946 007 Angle Bracket 94 946 517 P Fan Assembly Heat W...

Page 59: ...Regency P36D 10 Zero Clearance Direct Vent Gas Fireplace 59 59 parts list ...

Page 60: ...rifice 37 Natural Gas 904 390 Orifice 52 Propane 936 170 Orifice Gasket 910 036 Pilot Orifice NG 910 037 Pilot Orifice LP 79 791 535 Burner Assy 82 511 030 Burner Grate Assy 83 780 520 Rear Log Support Bracket 84 Deflector 85 780 930 Log Set 910 341 Thermopile 910 386 Thermocouple 910 432 Pilot Tube w nuts 910 096 Pilot Hood 910 030 Spark electrode 910 572 Remote receiver 911 127 Remote receiver b...

Page 61: ...ignette Platinum 515 923 Vignette Black Chrome 515 924 Vignette Black 515 926 Vignette Tuscan Sunset 2 515 918 Vignette Door Inlay Black Chrome 515 919 Vignette Door Inlay Metallic Black 515 920 Vignette Door Inlay Tuscan Sunset 515 922 Vignette Front Platinum 515 928 Vignette Finishing Trim w NCB 3 515 986 3 Sided Finishing Trim Not Shown ...

Page 62: ...62 Regency P36D 10 Zero Clearance Direct Vent Gas Fireplace 62 parts list Part Description 515 922 Flush louvers black 515 929 Safety Screen 948 223 Regency Logo Plate SAFETY SCREEN AND LOUVERS ...

Page 63: ...ed to the distributor or agent Transportation Prepaid if requested Porcelain Enamel Absolute perfection is either guaranteed nor commercially possible Any chips must be reported and inspected by an authorized dealer within three days of installation Reported damage after this time will be subject to rejection It is the general practice of FPI to charge for larger higher priced replacement parts an...

Page 64: ...________________ Serial No ___________________________________________________________ Register your Regency warranty online www regency fire com Reasons to register your product online today View and modify a list of all your registered products Request automatic email notification of new product updates Stay informed about the current promotions events and special offers on related products Prin...

Reviews: