Regency Horizon® HZ40E-10 Gas Fireplace
|
33
|
33
installation
Vertical Venting with Three (3) 90
o
Elbows
Vertical Venting with Three (3) 90
o
Elbows
Option
H
V
H + H1 V + V1
A)
1' Max.
1' Min.
3' Max.
3' Min.
With these options, max. total
pipe length is 30 feet with min.
of 11 feet total vertical and
max. 7 feet total horizontal.
Please note min. 1 foot
between 90
o
elbows is
required.
B)
2' Max. 2' Min. 4' Max. 5' Min.
C)
3' Max.
3' Min.'
5' Max. 7' Min.
D)
4' Max.
4' Min.
6' Max.
9' Min.
E)
5' Max. 5' Min. 7' Max.
11' Min.
Restrictor Position - Set 0 (factory setting)
One 90
o
elbow = Two 45
o
elbows.
One 90
o
elbow = Two 45
o
elbows.
Option V
H + H1 V + V1
A)
2' Min. 3' Max. 4' Min.
B) 3' Min. 4' Max. 6' Min.
C) 4' Min. 5' Max. 7' Min.
D) 5' Min. 6' Max. 8' Min.
E) 6' Min. 7' Max. 9' Min.
F)
7' Min. 8' Max. 10' Min.
With these options, max. total
pipe length is 30 feet with min.
of 10 feet total vertical and
max. 8 feet total horizontal.
Please note min. 1 foot
between 90
o
elbows is
required.
Restrictor Position - Set 0 (factory setting)