8
Regency FG38 FireGenie Freestanding Gas Stove
INSTALLATION
Conversion Kit for NG to LPG Model #756-969
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
Burner Orifi ce
Conversion Kit 756-969 Contains:
Qty. Part # Description
1 904-390 Burner Orifi ce #52
1 908-528 Red "LPG" label
1 908-255 Label "Converted to LPG"
1 918-270 Instruction Sheet
1)
Shut off the gas supply and unplug the
power cord.
2)
Open the front door and carefully remove
the logs and lava rock.
3)
Remove
burner.
4)
Remove burner orifi ce with a 1/2" wrench
and discard. Use a wrench to hold on to
the elbow behind the orifi ce.
5)
Reinstall new burner orifi ce LPG stamped
#52 and tighten.
6)
Adjust the burner aeration setting to 6.4mm
before installing the burner. Reverse steps
3) and 2).
7)
Stick the conversion label "This unit has
been converted to LPG" over top of the
serial number decal.
8)
Replace the yellow "NG" label with the red
"LPG" label.
9)
Remove the pedestal back cover by
removing the 4 Philips screws.
13)
Reverse steps 11 to 9.
14)
Turn on gas supply and plug in power cord.
Installer Notice:
These instructions must be left
with the appliance.
Control Box
Cover
Antenna
11)
Remove the control box cover by undoing
the 3 screws. Maneuver through antenna.
Jumper Location
Jumper
15) Adjusting the Outlet Pressure
All the adjustments must be carried out
in the following order:
Remove the modulator plastic cap (A)
using needle nose pliers.
Maximum pressure:
Turn the unit ON to
its highest input rating. Screw in the nut
(B) to increase the outlet pressure and
screw it out to decrease it. Use a 10 mm
wrench.
NOTE:
The outlet pressure must be set
to maximum 2.65 kPa.
Minimum pressure:
Remove one of the
cables connected to the electric modulator.
Keeping the nut (B) blocked, screw in the
screw (C) to increase the pressure and
screw it out to decrease it. Use a screwdriver
6 x 1 blade.
NOTE:
The outlet pressure must be set to
minimum 0.74 kPa.
After carrying out all adjustments, block the
setting screws with paint, taking care not to
obstruct the breather orifi ce of the pressure.
Put back the modulator plastic cap.
WARNING:
To ensure the correct operation
of the modulator it is necessary that the
plastic cap (A) is returned to its original
location.
16)
At the end of all setting and adjustment
operations, check electrical insulation and
gas leaks.
17)
Check operation of fl ame control.
18)
Check for proper fl ame appearance and
glow on logs.
C
B
A
Cable
Electric
Modulator
10)
Carefully pull out the control box.
NOTE: The control box is held in place with
velcro.
12)
Remove the jumper using a plier.