Regency Bellavista™ B41XT Gas Fireplace
59
MAINTENANCE
VALVE REPLACEMENT
11)
Remove the 14 screws securing the
valve tray assembly in place (Diagram
7) and then lift the entire assembly out
(Diagram 8). Also remove the valve gasket.
1)
Shut off the gas and electrical supply.
2)
Remove the louvers
3)
Open
the
fl ush door and remove the door.
4)
Remove the logs.
5)
Remove the burner/grate assembly by
removing the 2 screws.
Diagram 1: Remove the left and right screws.
Diagram 2: Slide burner assembly to the right
and then remove.
7)
Remove the 2 screws securing the rear log
tray and lift out. Diagram 3
8)
Remove the 2 screws securing the burner
tray - lift base tray up and out. Diagram
4a and 4b.
10)
Disconnect the wall switch wires from the
valve. (see Diagram 6)
Diagram 5
Diagram 4a
Diagram 4b
Diagram 3
Diagram 6
Diagram 7
Diagram 8
INSTALLING VALVE
1)
Place new valve tray and gasket into position.
2)
Reinstall the 14 hold down screws.
3)
Hook up the 2 TP and 2 TH wires to the ap-
propriate connections on the valve.
4)
Reinstall the rear log tray.
5)
Install burner/grate assembly
6)
Hook up the gas line and check for gas leaks
with a soap and water solution or a gas leak
detector. (Do not use open fl ame for leak
testing.)
7)
Fire up the unit temporarily
8)
Check the manifold pressure.
9)
Reinstall the logs and brick panels as
needed.
10)
Reinstall the door and replace the louvers.
11)
Fire up the unit again and check for proper
fl ame appearance and glow on logs.
6)
Slide the burner assembly to the right to
release it from the orifi ce, then lift it out.
9)
Disconnect the inlet gas line. See Diagram
5.