City Series CB60EPV
|
79
installation
920-210a
06.08.20
12
CV72EPV / CB72EPVCB40EPV/CC40EPV/CV40EPV
Inline Power Vent Vertical or Hortizontal Installation Instructions
Gas Power Vent Installation--Wiring the Power Vent to the Unit
1. Remove exterior side panels and bottom panels (if installed) to gain
access to junction box (Diagram 1).
BX cable through strain relief
Remove 2 panels
(single-sided
models)
Remove 1 panel
(3-sided models)
2. Remove access panel by lifting panel up and out (Diagram 2). Unscrew
1 x Phillips head screw to gain access to junction box (Diagram 3).
3. Strip 24" of BX exposing wires, then run BX through strain relief on
right side of the unit into the junction box (Diagrams 4 & 5).
Note: The ground wire must stay out of the junction box as this will be
attached later. Only the 4 colored wires go into the junction box.
4. Join Powervent and BX cable wires together by firstly splicing 1" off
wires-- join black to black, white to white (Diagram 6).
5. Join the Pressure switch and BX cable wires by splicing 1" off wires-
-join red to red and blue to blue (Diagram 7).
6. After the power and pressure switches have been connected, place
wired connections into junction box and screw the junction cover
plate back in place.
7. To make the ground connection, release the front right glass gasket
pad by turning clips (3 total) counter-clockwise (Diagram 8).
Remove Access
Panel
Remove 1 Screw
Strain relief
Glass gasket pad
Diagram 1
Single-sided model shown
Diagram 5
Diagram 6
Diagram 7
Diagram 8
Diagram 2
Diagram 3
Diagram 4
Gas Power Vent Installation - Wiring the Power Vent to the Unit
Summary of Contents for 686-927