installation
Vertical Inline Power Vent Terminations
Flex Pipe
Diagram 4
20. Put a bead of caulking on the exterior between the outer pipe and
flashing to prevent water from penetrating the chimney system.
21. Slide storm collar over pipe length until it reaches the flashing.
22. Install termination cap by twist locking it.
23. Secure the flashing to the roof using screws
Note
: Any closets or storage spaces which the vent passes through
must be enclosed.
Diagram 3
Diagram 3b
19. Slide the finished length up towards the flashing ensuring the length
of pipe is a minimum of 2 feet measured from the top of the roof.
Level the chimney and secure using the roof support provided with
kit to bottom side of the roof as shown using a minimum of 2 screws
per side- see Diagram 3b. See Diagram 4 for roof pitch and height
requirements. See Diagram 3a for securing method if 2 ft. is insufficient
and additional lengths are required, this may be purchased separately.
See Simpson Duravent components list in the instruction manual for
part numbers.
Flex Pipe
Ceiling Firestop
Roof Support / Brace
Flashing
Storm Collar
Termination Cap
Ceiling Firestop
Inline Power Vent Terminal
Inner Pipe Adaptor (shown inside flex pipe)
Enclosure
Flex Pipe
Ceiling Firestop
Roof Support
Flashing
Elbow Support
Termination Cap
Storm Collar
Ceiling Firestop
Support to prevent sagging
Inline Power Vent Terminal
Enclosure
Ceiling firestop
Flashing
Termination Cap
Storm Collar
Roof support
Ceiling firestop
Roof Pitch
Minimum
Vent Height
Feet Meters
flat to 7/12
2
0.61
over 7/12 to 8/12
2
0.61
over 8/12 to 9/12
2
0.61
over 9/12 to 10/12
2.5
0.76
over 10/12 to 11/12
3.25
0.99
over 11/12 to 12/12
4
1.22
over 12/12 to 14/12
5
1.52
over 14/12 to 16/12
6
1.83
over 16/12 to 18/12
7
2.13
over 18/12 to 20/12
7.5
2.29
over 20/12 to 21/12
8
2.44